Merge pull request #1439 from dalathegreat/bugfix/precharge-osc
Precharge: Avoid oscillation in precharge pin incase it fails/timeouts
This commit is contained in:
commit
01f03d6726
3 changed files with 15 additions and 4 deletions
|
@ -64,6 +64,14 @@ void handle_precharge_control(unsigned long currentMillis) {
|
||||||
auto hia4v1_pin = esp32hal->HIA4V1_PIN();
|
auto hia4v1_pin = esp32hal->HIA4V1_PIN();
|
||||||
auto inverter_disconnect_contactor_pin = esp32hal->INVERTER_DISCONNECT_CONTACTOR_PIN();
|
auto inverter_disconnect_contactor_pin = esp32hal->INVERTER_DISCONNECT_CONTACTOR_PIN();
|
||||||
|
|
||||||
|
// If we're in FAILURE state, completely disable any further precharge attempts
|
||||||
|
if (datalayer.system.status.precharge_status == AUTO_PRECHARGE_FAILURE) {
|
||||||
|
pinMode(hia4v1_pin, OUTPUT);
|
||||||
|
digitalWrite(hia4v1_pin, LOW);
|
||||||
|
digitalWrite(inverter_disconnect_contactor_pin, ON);
|
||||||
|
return; // Exit immediately - no further processing allowed. Reboot required to recover
|
||||||
|
}
|
||||||
|
|
||||||
int32_t target_voltage = datalayer.battery.status.voltage_dV;
|
int32_t target_voltage = datalayer.battery.status.voltage_dV;
|
||||||
int32_t external_voltage = datalayer_extended.meb.BMS_voltage_intermediate_dV;
|
int32_t external_voltage = datalayer_extended.meb.BMS_voltage_intermediate_dV;
|
||||||
|
|
||||||
|
@ -128,11 +136,13 @@ void handle_precharge_control(unsigned long currentMillis) {
|
||||||
pinMode(hia4v1_pin, OUTPUT);
|
pinMode(hia4v1_pin, OUTPUT);
|
||||||
digitalWrite(hia4v1_pin, LOW);
|
digitalWrite(hia4v1_pin, LOW);
|
||||||
digitalWrite(inverter_disconnect_contactor_pin, ON);
|
digitalWrite(inverter_disconnect_contactor_pin, ON);
|
||||||
datalayer.system.status.precharge_status = AUTO_PRECHARGE_OFF;
|
datalayer.system.status.precharge_status = AUTO_PRECHARGE_FAILURE;
|
||||||
#ifdef DEBUG_LOG
|
#ifdef DEBUG_LOG
|
||||||
logging.printf("Precharge: Disabled (timeout reached / BMS fault) -> AUTO_PRECHARGE_OFF\n");
|
logging.printf("Precharge: CRITICAL FAILURE (timeout/BMS fault) -> REQUIRES REBOOT\n");
|
||||||
#endif
|
#endif
|
||||||
set_event(EVENT_AUTOMATIC_PRECHARGE_FAILURE, 0);
|
set_event(EVENT_AUTOMATIC_PRECHARGE_FAILURE, 0);
|
||||||
|
// Force stop any further precharge attempts
|
||||||
|
datalayer.system.settings.start_precharging = false;
|
||||||
|
|
||||||
// Add event
|
// Add event
|
||||||
} else if (datalayer.system.status.battery_allows_contactor_closing) {
|
} else if (datalayer.system.status.battery_allows_contactor_closing) {
|
||||||
|
|
|
@ -263,7 +263,7 @@ String get_event_message_string(EVENTS_ENUM_TYPE event) {
|
||||||
case EVENT_PRECHARGE_FAILURE:
|
case EVENT_PRECHARGE_FAILURE:
|
||||||
return "Battery failed to precharge. Check that capacitor is seated on high voltage output.";
|
return "Battery failed to precharge. Check that capacitor is seated on high voltage output.";
|
||||||
case EVENT_AUTOMATIC_PRECHARGE_FAILURE:
|
case EVENT_AUTOMATIC_PRECHARGE_FAILURE:
|
||||||
return "Automatic precharge failed to reach target voltae.";
|
return "Automatic precharge FAILURE. Failed to reach target voltage or BMS timeout. Reboot emulator to retry!";
|
||||||
case EVENT_INTERNAL_OPEN_FAULT:
|
case EVENT_INTERNAL_OPEN_FAULT:
|
||||||
return "High voltage cable removed while battery running. Opening contactors!";
|
return "High voltage cable removed while battery running. Opening contactors!";
|
||||||
case EVENT_INVERTER_OPEN_CONTACTOR:
|
case EVENT_INVERTER_OPEN_CONTACTOR:
|
||||||
|
|
|
@ -27,7 +27,8 @@ enum PrechargeState {
|
||||||
AUTO_PRECHARGE_START,
|
AUTO_PRECHARGE_START,
|
||||||
AUTO_PRECHARGE_PRECHARGING,
|
AUTO_PRECHARGE_PRECHARGING,
|
||||||
AUTO_PRECHARGE_OFF,
|
AUTO_PRECHARGE_OFF,
|
||||||
AUTO_PRECHARGE_COMPLETED
|
AUTO_PRECHARGE_COMPLETED,
|
||||||
|
AUTO_PRECHARGE_FAILURE
|
||||||
};
|
};
|
||||||
|
|
||||||
#define DISCHARGING 1
|