mirror of
https://github.com/dalathegreat/Battery-Emulator.git
synced 2025-10-03 09:49:32 +02:00
Make custom-BMS voltage limits configurable via settings
This commit is contained in:
parent
552c304be4
commit
0d8bc06f04
17 changed files with 156 additions and 91 deletions
|
@ -171,6 +171,12 @@
|
|||
// 3000 = 300.0V, Target discharge voltage (Value can be tuned on the fly via webserver). Not used unless BATTERY_USE_VOLTAGE_LIMITS = true
|
||||
#define BATTERY_MAX_DISCHARGE_VOLTAGE 3000
|
||||
|
||||
/* Pack/cell voltage limits for custom-BMS batteries (RJXZS, Daly, etc.) */
|
||||
//#define MAX_CUSTOM_PACK_VOLTAGE_DV 5000 // 5000 = 500.0V , Maximum pack voltage in decivolts
|
||||
//#define MIN_CUSTOM_PACK_VOLTAGE_DV 2500 // 2500 = 250.0V , Minimum pack voltage in decivolts
|
||||
//#define MAX_CUSTOM_CELL_VOLTAGE_MV 4250 // 4250 = 4.250V , Maximum cell voltage in millivolts (4250 = 4.250V)
|
||||
//#define MIN_CUSTOM_CELL_VOLTAGE_MV 2650 // 2650 = 2.650V , Minimum cell voltage in millivolts (2650 = 2.650V)
|
||||
|
||||
/* LED settings. Optional customization for how the blinking pattern on the LED should behave.
|
||||
* CLASSIC - Slow up/down ramp. If CLASSIC, then a ramp up and ramp down will finish in LED_PERIOD_MS milliseconds
|
||||
* FLOW - Ramp up/down depending on flow of energy
|
||||
|
|
Loading…