@ -49,14 +49,14 @@ Change the following only if your inverter is generating fault codes about volta
|
||||||
.ext_ID = true,
|
.ext_ID = true,
|
||||||
.DLC = 8,
|
.DLC = 8,
|
||||||
.ID = 0x7320,
|
.ID = 0x7320,
|
||||||
.data = {TOTAL_CELL_AMOUNT, (uint8_t)(TOTAL_CELL_AMOUNT >> 8), MODULES_IN_SERIES,
|
.data = {(TOTAL_CELL_AMOUNT & 0xFF), (uint8_t)(TOTAL_CELL_AMOUNT >> 8), MODULES_IN_SERIES,
|
||||||
CELLS_PER_MODULE, (uint8_t)(VOLTAGE_LEVEL & 0x00FF), (uint8_t)(VOLTAGE_LEVEL >> 8),
|
CELLS_PER_MODULE, (uint8_t)(VOLTAGE_LEVEL & 0x00FF), (uint8_t)(VOLTAGE_LEVEL >> 8),
|
||||||
AH_CAPACITY, (uint8_t)(AH_CAPACITY >> 8)}};
|
AH_CAPACITY, (uint8_t)(AH_CAPACITY >> 8)}};
|
||||||
CAN_frame PYLON_7321 = {.FD = false,
|
CAN_frame PYLON_7321 = {.FD = false,
|
||||||
.ext_ID = true,
|
.ext_ID = true,
|
||||||
.DLC = 8,
|
.DLC = 8,
|
||||||
.ID = 0x7321,
|
.ID = 0x7321,
|
||||||
.data = {TOTAL_CELL_AMOUNT, (uint8_t)(TOTAL_CELL_AMOUNT >> 8), MODULES_IN_SERIES,
|
.data = {(TOTAL_CELL_AMOUNT & 0xFF), (uint8_t)(TOTAL_CELL_AMOUNT >> 8), MODULES_IN_SERIES,
|
||||||
CELLS_PER_MODULE, (uint8_t)(VOLTAGE_LEVEL & 0x00FF), (uint8_t)(VOLTAGE_LEVEL >> 8),
|
CELLS_PER_MODULE, (uint8_t)(VOLTAGE_LEVEL & 0x00FF), (uint8_t)(VOLTAGE_LEVEL >> 8),
|
||||||
AH_CAPACITY, (uint8_t)(AH_CAPACITY >> 8)}};
|
AH_CAPACITY, (uint8_t)(AH_CAPACITY >> 8)}};
|
||||||
CAN_frame PYLON_4210 = {.FD = false,
|
CAN_frame PYLON_4210 = {.FD = false,
|
||||||
|
|