Replace faulty cap check with welded contactor check

This commit is contained in:
Daniel Öster 2024-11-04 10:17:55 +02:00
parent 56171aa5f1
commit 1f96681e94
3 changed files with 11 additions and 7 deletions

View file

@ -150,6 +150,7 @@ void init_events(void) {
events.entries[EVENT_CAN_RX_WARNING].level = EVENT_LEVEL_WARNING;
events.entries[EVENT_CAN_TX_FAILURE].level = EVENT_LEVEL_ERROR;
events.entries[EVENT_CAN_INVERTER_MISSING].level = EVENT_LEVEL_WARNING;
events.entries[EVENT_CONTACTOR_WELDED].level = EVENT_LEVEL_WARNING;
events.entries[EVENT_WATER_INGRESS].level = EVENT_LEVEL_ERROR;
events.entries[EVENT_CHARGE_LIMIT_EXCEEDED].level = EVENT_LEVEL_INFO;
events.entries[EVENT_DISCHARGE_LIMIT_EXCEEDED].level = EVENT_LEVEL_INFO;
@ -281,6 +282,8 @@ const char* get_event_message_string(EVENTS_ENUM_TYPE event) {
return "ERROR: CAN messages failed to transmit, or no one on the bus to ACK the message!";
case EVENT_CAN_INVERTER_MISSING:
return "Warning: Inverter not sending messages on CAN bus. Check wiring!";
case EVENT_CONTACTOR_WELDED:
return "Warning: Contactors sticking/welded. Inspect battery with caution!";
case EVENT_CHARGE_LIMIT_EXCEEDED:
return "Info: Inverter is charging faster than battery is allowing.";
case EVENT_DISCHARGE_LIMIT_EXCEEDED: