Improve CAN logging
Added ability to output values via Serial easily
This commit is contained in:
parent
2142c913b0
commit
27b33d9977
1 changed files with 52 additions and 27 deletions
|
@ -11,6 +11,7 @@
|
|||
#define BATTERY_WH_MAX 30000 //Battery size in Wh (Maximum value Fronius accepts is 60000 [60kWh])
|
||||
#define MAXPERCENTAGE 800 //80.0% , Max percentage the battery will charge to (App will show 100% once this value is reached)
|
||||
#define MINPERCENTAGE 200 //20.0% , Min percentage the battery will discharge to (App will show 0% once this value is reached)
|
||||
byte printValues = 1; //Should modbus values be printed to serial output?
|
||||
|
||||
/* Do not change code below unless you are sure what you are doing */
|
||||
//CAN parameters
|
||||
|
@ -32,7 +33,7 @@ CAN_frame_t LEAF_50C = {.MsgID = 0x50C, LEAF_50C.FIR.B.DLC = 8, LEAF_50C.FIR.B.F
|
|||
#define LB_MAX_SOC 1000 //LEAF BMS never goes over this value. We use this info to rescale SOC% sent to Fronius
|
||||
#define LB_MIN_SOC 0 //LEAF BMS never goes below this value. We use this info to rescale SOC% sent to Fronius
|
||||
uint16_t LB_Discharge_Power_Limit = 0; //Limit in kW
|
||||
uint16_t LB_MAX_POWER_FOR_CHARGER = 0; //Limit in kW
|
||||
int16_t LB_MAX_POWER_FOR_CHARGER = 0; //Limit in kW
|
||||
int16_t LB_SOC = 500; //0 - 100.0 % (0-1000)
|
||||
uint16_t LB_Wh_Remaining = 0; //Amount of energy in battery, in Wh
|
||||
uint16_t LB_GIDS = 0;
|
||||
|
@ -52,7 +53,7 @@ uint8_t LB_Failsafe_Status = 0; //LB_STATUS = 000b = normal start Request
|
|||
//101b = Caution Lamp Request & Main Relay OFF Request
|
||||
//110b = Caution Lamp Request & Charging Mode Stop Request
|
||||
//111b = Caution Lamp Request & Main Relay OFF Request
|
||||
byte LB_Interlock = 0; //Contains info on if HV leads are seated
|
||||
byte LB_Interlock = 0; //Contains info on if HV leads are seated (Note, to use this both HV connectors need to be inserted)
|
||||
byte LB_Full_CHARGE_flag = 0; //LB_FCHGEND , Goes to 1 if battery is fully charged
|
||||
byte LB_MainRelayOn_flag = 0; //No-Permission=0, Main Relay On Permission=1
|
||||
byte LB_Capacity_Empty = 0; //LB_EMPTY, , Goes to 1 if battery is empty
|
||||
|
@ -66,18 +67,18 @@ unsigned long previousMillisModbus = 0; //will store last time a modbus register
|
|||
uint16_t mbPV[MB_RTU_NUM_VALUES]; // process variable memory: produced by sensors, etc., cyclic read by PLC via modbus TCP
|
||||
|
||||
uint16_t capacity_Wh_startup = BATTERY_WH_MAX;
|
||||
uint16_t MaxPower = 40960; //41kW TODO, fetch from LEAF battery (or does it matter, polled after startup?)
|
||||
uint16_t MaxVoltage = 4040; //(404.4V), if higher charging is not possible (goes into forced discharge)
|
||||
uint16_t MinVoltage = 3100; //Min Voltage (310.0V), if lower Gen24 disables battery
|
||||
uint16_t BatteryVoltage = 3700;
|
||||
uint16_t max_power = 40960; //41kW
|
||||
uint16_t max_voltage = 4040; //(404.4V), if higher charging is not possible (goes into forced discharge)
|
||||
uint16_t min_voltage = 3100; //Min Voltage (310.0V), if lower Gen24 disables battery
|
||||
uint16_t battery_voltage = 3700;
|
||||
uint16_t SOC = 5000; //SOC 0-100.00% //Updates later on from CAN
|
||||
uint16_t SOH = 9900; //SOH 0-100.00% //Updates later on from CAN
|
||||
uint16_t capacity_Wh = BATTERY_WH_MAX; //Updates later on from CAN
|
||||
uint16_t remaining_capacity_Wh = BATTERY_WH_MAX; //Updates later on from CAN
|
||||
uint16_t max_target_discharge_power = 0; //0W (0W > restricts to no discharge) //Updates later on from CAN
|
||||
uint16_t max_target_charge_power = 4312; //4.3kW (during charge), both 307&308 can be set (>0) at the same time //Updates later on from CAN
|
||||
uint16_t TemperatureMax = 50; //Todo, read from LEAF pack, uint not ok
|
||||
uint16_t TemperatureMin = 60; //Todo, read from LEAF pack, uint not ok
|
||||
uint16_t temperature_max = 50; //Todo, read from LEAF pack, uint not ok
|
||||
uint16_t temperature_min = 60; //Todo, read from LEAF pack, uint not ok
|
||||
uint16_t bms_char_dis_status; //0 idle, 1 discharging, 2, charging
|
||||
uint16_t bms_status = 0; //ACTIVE - [0..5]<>[STANDBY,INACTIVE,DARKSTART,ACTIVE,FAULT,UPDATING]
|
||||
|
||||
|
@ -150,6 +151,7 @@ void loop()
|
|||
void update_values_leaf_battery()
|
||||
{ //This function maps all the values fetched via CAN to the correct parameters used for modbus
|
||||
SOH = (LB_SOH * 100); //Increase range from 99% -> 99.00%
|
||||
|
||||
//Calculate the SOC% value to send to Fronius
|
||||
LB_SOC = LB_MIN_SOC + (LB_MAX_SOC - LB_MIN_SOC) * (LB_SOC - MINPERCENTAGE) / (MAXPERCENTAGE - MINPERCENTAGE);
|
||||
if (LB_SOC < 0)
|
||||
|
@ -160,32 +162,55 @@ void update_values_leaf_battery()
|
|||
{ //We are in the real SOC% range of 80-100%, always set SOC sent to Fronius as 100%
|
||||
LB_SOC = 1000;
|
||||
}
|
||||
SOC = (LB_SOC * 10); //increase range from 0-100.0 -> 100.00
|
||||
SOC = (LB_SOC * 10); //increase LB_SOC range from 0-100.0 -> 100.00
|
||||
|
||||
BatteryVoltage = (LB_Total_Voltage*10); //One more decimal needed
|
||||
battery_voltage = (LB_Total_Voltage*10); //One more decimal needed
|
||||
|
||||
MaxPower = (LB_Discharge_Power_Limit * 1000); //kW to W
|
||||
capacity_Wh = (LB_Max_GIDS * WH_PER_GID);
|
||||
|
||||
remaining_capacity_Wh = LB_Wh_Remaining;
|
||||
if(LB_Discharge_Power_Limit > 30) //if >60kW can be pulled from battery
|
||||
|
||||
if(LB_Discharge_Power_Limit > 30) //if >30kW can be pulled from battery
|
||||
{
|
||||
max_target_discharge_power = 30000; //cap value so we don't go the Fronius limits
|
||||
max_target_discharge_power = 30000; //cap value so we don't go over the Fronius limits
|
||||
}
|
||||
else
|
||||
{
|
||||
max_target_discharge_power = (LB_Discharge_Power_Limit * 1000); //kW to W
|
||||
}
|
||||
Serial.println(max_target_discharge_power);
|
||||
if(LB_MAX_POWER_FOR_CHARGER > 60)
|
||||
|
||||
if(LB_MAX_POWER_FOR_CHARGER > 30) //if >30kW can be put into the battery
|
||||
{
|
||||
max_target_charge_power = 60000; //cap value so we don't go over 16bits
|
||||
max_target_charge_power = 30000; //cap value so we don't go over the Fronius limits
|
||||
}
|
||||
if(LB_MAX_POWER_FOR_CHARGER < 0) //LB_MAX_POWER_FOR_CHARGER can actually go to -10kW
|
||||
{
|
||||
max_target_charge_power = 0; //cap calue so we dont do under the Fronius limits
|
||||
}
|
||||
else
|
||||
{
|
||||
max_target_charge_power = (LB_MAX_POWER_FOR_CHARGER * 1000); //kW to W
|
||||
}
|
||||
TemperatureMin = 50; //hardcoded, todo, read from 5C0
|
||||
TemperatureMax = 60; //hardcoded, todo, read from 5C0
|
||||
|
||||
temperature_min = 50; //hardcoded, todo, read from 5C0
|
||||
|
||||
temperature_max = 60; //hardcoded, todo, read from 5C0
|
||||
|
||||
if(printValues)
|
||||
{
|
||||
Serial.println("SOH%: ");
|
||||
Serial.println(SOH);
|
||||
Serial.println("SOC%: ");
|
||||
Serial.println(SOC);
|
||||
Serial.println("Max discharge power: ");
|
||||
Serial.println(max_target_discharge_power);
|
||||
Serial.println("Max discharge power: ");
|
||||
Serial.println(max_target_charge_power);
|
||||
Serial.println("Temperature Min: ");
|
||||
Serial.println(temperature_min);
|
||||
Serial.println("Temperature Max: ");
|
||||
Serial.println(temperature_max);
|
||||
}
|
||||
}
|
||||
|
||||
void handle_static_data_modbus() {
|
||||
|
@ -212,10 +237,10 @@ void handle_update_data_modbusp201() {
|
|||
system_data[0] = 0; // Id.: p201 Value.: 0 Scaled value.: 0 Comment.: Always 0
|
||||
system_data[1] = 0; // Id.: p202 Value.: 0 Scaled value.: 0 Comment.: Always 0
|
||||
system_data[2] = (capacity_Wh_startup); // Id.: p203 Value.: 32000 Scaled value.: 32kWh Comment.: Capacity rated, maximum value is 60000 (60kWh)
|
||||
system_data[3] = (capacity_Wh_startup); // Id.: p204 Value.: 32000 Scaled value.: 32kWh Comment.: Nominal capacity
|
||||
system_data[4] = (MaxPower); // Id.: p205 Value.: 14500 Scaled value.: 30,42kW Comment.: Max Charge/Discharge Power=10.24kW
|
||||
system_data[5] = (MaxVoltage); // Id.: p206 Value.: 3667 Scaled value.: 362,7VDC Comment.: Max Voltage, if higher charging is not possible (goes into forced discharge)
|
||||
system_data[6] = (MinVoltage); // Id.: p207 Value.: 2776 Scaled value.: 277,6VDC Comment.: Min Voltage, if lower Gen24 disables battery
|
||||
system_data[3] = (max_power); // Id.: p204 Value.: 32000 Scaled value.: 32kWh Comment.: Nominal capacity
|
||||
system_data[4] = (max_power); // Id.: p205 Value.: 14500 Scaled value.: 30,42kW Comment.: Max Charge/Discharge Power=10.24kW (lowest value of 204 and 205 will be enforced by Gen24)
|
||||
system_data[5] = (max_voltage); // Id.: p206 Value.: 3667 Scaled value.: 362,7VDC Comment.: Max Voltage, if higher charging is not possible (goes into forced discharge)
|
||||
system_data[6] = (min_voltage); // Id.: p207 Value.: 2776 Scaled value.: 277,6VDC Comment.: Min Voltage, if lower Gen24 disables battery
|
||||
system_data[7] = 53248; // Id.: p208 Value.: 53248 Scaled value.: 53248 Comment.: Always 53248 for this BYD, Peak Charge power?
|
||||
system_data[8] = 10; // Id.: p209 Value.: 10 Scaled value.: 10 Comment.: Always 10
|
||||
system_data[9] = 53248; // Id.: p210 Value.: 53248 Scaled value.: 53248 Comment.: Always 53248 for this BYD, Peak Discharge power?
|
||||
|
@ -240,7 +265,7 @@ void handle_update_data_modbusp301() {
|
|||
bms_status = 3; //Todo add logic here
|
||||
|
||||
if (bms_status == 3) {
|
||||
battery_data[8] = BatteryVoltage; // Id.: p309 Value.: 3161 Scaled value.: 316,1VDC Comment.: Batt Voltage outer (0 if status !=3, maybe a contactor closes when active): 173.4V
|
||||
battery_data[8] = battery_voltage; // Id.: p309 Value.: 3161 Scaled value.: 316,1VDC Comment.: Batt Voltage outer (0 if status !=3, maybe a contactor closes when active): 173.4V
|
||||
} else {
|
||||
battery_data[8] = 0;
|
||||
}
|
||||
|
@ -254,10 +279,10 @@ void handle_update_data_modbusp301() {
|
|||
battery_data[7] = max_target_charge_power; // Id.: p308 Value.: 25604 Scaled value.: 25,604kW Comment.: max/target charge power: 4.3kW (during charge), both 307&308 can be set (>0) at the same time
|
||||
//Battery_data[8] set previously in function // Id.: p309 Value.: 3161 Scaled value.: 316,1VDC Comment.: Batt Voltage outer (0 if status !=3, maybe a contactor closes when active): 173.4V
|
||||
battery_data[9] = 2000; // Id.: p310 Value.: 64121 Scaled value.: 6412,1W Comment.: Current Power to API: if>32768... -(65535-61760)=3775W
|
||||
battery_data[10] = BatteryVoltage; // Id.: p311 Value.: 3161 Scaled value.: 316,1VDC Comment.: Batt Voltage inner: 173.2V (LEAF voltage is in whole volts, need to add a decimal)
|
||||
battery_data[10] = battery_voltage; // Id.: p311 Value.: 3161 Scaled value.: 316,1VDC Comment.: Batt Voltage inner: 173.2V (LEAF voltage is in whole volts, need to add a decimal)
|
||||
battery_data[11] = 2000; // Id.: p312 Value.: 64121 Scaled value.: 6412,1W Comment.: p310
|
||||
battery_data[12] = TemperatureMin; // Id.: p313 Value.: 75 Scaled value.: 7,5 Comment.: temp min: 14 degrees (if below 0....65535-t)
|
||||
battery_data[13] = TemperatureMax; // Id.: p314 Value.: 95 Scaled value.: 9,5 Comment.: temp max: 15 degrees (if below 0....65535-t)
|
||||
battery_data[12] = temperature_min; // Id.: p313 Value.: 75 Scaled value.: 7,5 Comment.: temp min: 14 degrees (if below 0....65535-t)
|
||||
battery_data[13] = temperature_max; // Id.: p314 Value.: 95 Scaled value.: 9,5 Comment.: temp max: 15 degrees (if below 0....65535-t)
|
||||
battery_data[14] = 0; // Id.: p315 Value.: 0 Scaled value.: 0 Comment.: always 0
|
||||
battery_data[15] = 0; // Id.: p316 Value.: 0 Scaled value.: 0 Comment.: always 0
|
||||
battery_data[16] = 16; // Id.: p317 Value.: 0 Scaled value.: 0 Comment.: counter charge hi
|
||||
|
@ -266,7 +291,7 @@ void handle_update_data_modbusp301() {
|
|||
battery_data[19] = 0; // Id.: p320 Value.: 0 Scaled value.: 0 Comment.: always 0
|
||||
battery_data[20] = 13; // Id.: p321 Value.: 0 Scaled value.: 0 Comment.: counter discharge hi
|
||||
battery_data[21] = 52064; // Id.: p322 Value.: 0 Scaled value.: 0 Comment.: counter discharge lo....65536*92+7448 = 6036760 Wh?
|
||||
battery_data[22] = 80; // Id.: p323 Value.: 0 Scaled value.: 0 Comment.: temp? (23 degrees)
|
||||
battery_data[22] = 230; // Id.: p323 Value.: 0 Scaled value.: 0 Comment.: device temperature (23 degrees)
|
||||
battery_data[23] = SOH; // Id.: p324 Value.: 9900 Scaled value.: 99% Comment.: SOH
|
||||
static uint16_t i = 300;
|
||||
memcpy(&mbPV[i], battery_data, sizeof(battery_data));
|
||||
|
|