mirror of
https://github.com/dalathegreat/Battery-Emulator.git
synced 2025-10-05 10:49:42 +02:00
Fix double battery contactor control settings
This commit is contained in:
parent
f1061b0822
commit
4469d07b82
1 changed files with 7 additions and 7 deletions
|
@ -170,9 +170,9 @@ void handle_contactors() {
|
|||
handle_BMSpower(); // Some batteries need to be periodically power cycled
|
||||
}
|
||||
|
||||
#ifdef CONTACTOR_CONTROL_DOUBLE_BATTERY
|
||||
handle_contactors_battery2();
|
||||
#endif // CONTACTOR_CONTROL_DOUBLE_BATTERY
|
||||
if (contactor_control_enabled_double_battery) {
|
||||
handle_contactors_battery2();
|
||||
}
|
||||
|
||||
if (contactor_control_enabled) {
|
||||
// First check if we have any active errors, incase we do, turn off the battery
|
||||
|
@ -272,17 +272,17 @@ void handle_contactors() {
|
|||
}
|
||||
}
|
||||
|
||||
#ifdef CONTACTOR_CONTROL_DOUBLE_BATTERY
|
||||
void handle_contactors_battery2() {
|
||||
auto second_contactors = esp32hal->SECOND_BATTERY_CONTACTORS_PIN();
|
||||
|
||||
if ((contactorStatus == COMPLETED) && datalayer.system.status.battery2_allowed_contactor_closing) {
|
||||
set(SECOND_BATTERY_CONTACTORS_PIN, ON);
|
||||
set(second_contactors, ON);
|
||||
datalayer.system.status.contactors_battery2_engaged = true;
|
||||
} else { // Closing contactors on secondary battery not allowed
|
||||
set(SECOND_BATTERY_CONTACTORS_PIN, OFF);
|
||||
set(second_contactors, OFF);
|
||||
datalayer.system.status.contactors_battery2_engaged = false;
|
||||
}
|
||||
}
|
||||
#endif
|
||||
|
||||
/* PERIODIC_BMS_RESET - Once every 24 hours we remove power from the BMS_power pin for 30 seconds.
|
||||
REMOTE_BMS_RESET - Allows the user to remotely powercycle the BMS by sending a command to the emulator via MQTT.
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue