Batteries implement HTML renderers for status and commands

This commit is contained in:
Jaakko Haakana 2025-06-01 09:59:46 +03:00
parent d1fb28337e
commit 662ae57d2b
48 changed files with 2345 additions and 2020 deletions

View file

@ -0,0 +1,108 @@
#ifndef _VOLVO_SPA_HTML_H
#define _VOLVO_SPA_HTML_H
#include "../datalayer/datalayer.h"
#include "../datalayer/datalayer_extended.h"
#include "src/devboard/webserver/BatteryHtmlRenderer.h"
class VolvoSpaHtmlRenderer : public BatteryHtmlRenderer {
public:
String get_status_html() {
String content;
content += "<h4>BECM reported SOC: " + String(datalayer_extended.VolvoPolestar.soc_bms) + "</h4>";
content += "<h4>Calculated SOC: " + String(datalayer_extended.VolvoPolestar.soc_calc) + "</h4>";
content += "<h4>Rescaled SOC: " + String(datalayer_extended.VolvoPolestar.soc_rescaled / 10) + "</h4>";
content += "<h4>BECM reported SOH: " + String(datalayer_extended.VolvoPolestar.soh_bms) + "</h4>";
content += "<h4>BECM supply voltage: " + String(datalayer_extended.VolvoPolestar.BECMsupplyVoltage) + " mV</h4>";
content += "<h4>HV voltage: " + String(datalayer_extended.VolvoPolestar.BECMBatteryVoltage) + " V</h4>";
content += "<h4>HV current: " + String(datalayer_extended.VolvoPolestar.BECMBatteryCurrent) + " A</h4>";
content += "<h4>Dynamic max voltage: " + String(datalayer_extended.VolvoPolestar.BECMUDynMaxLim) + " V</h4>";
content += "<h4>Dynamic min voltage: " + String(datalayer_extended.VolvoPolestar.BECMUDynMinLim) + " V</h4>";
content +=
"<h4>Discharge power limit 1: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimDcha1) + " kW</h4>";
content +=
"<h4>Discharge soft power limit: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimDchaSoft) + " kW</h4>";
content +=
"<h4>Discharge power limit slow aging: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimDchaSlowAgi) +
" kW</h4>";
content +=
"<h4>Charge power limit slow aging: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimChrgSlowAgi) +
" kW</h4>";
content += "<h4>HV system relay status: ";
switch (datalayer_extended.VolvoPolestar.HVSysRlySts) {
case 0:
content += String("Open");
break;
case 1:
content += String("Closed");
break;
case 2:
content += String("KeepStatus");
break;
case 3:
content += String("OpenAndRequestActiveDischarge");
break;
default:
content += String("Not valid");
}
content += "</h4><h4>HV system relay status 1: ";
switch (datalayer_extended.VolvoPolestar.HVSysDCRlySts1) {
case 0:
content += String("Open");
break;
case 1:
content += String("Closed");
break;
case 2:
content += String("KeepStatus");
break;
case 3:
content += String("Fault");
break;
default:
content += String("Not valid");
}
content += "</h4><h4>HV system relay status 2: ";
switch (datalayer_extended.VolvoPolestar.HVSysDCRlySts2) {
case 0:
content += String("Open");
break;
case 1:
content += String("Closed");
break;
case 2:
content += String("KeepStatus");
break;
case 3:
content += String("Fault");
break;
default:
content += String("Not valid");
}
content += "</h4><h4>HV system isolation resistance monitoring status: ";
switch (datalayer_extended.VolvoPolestar.HVSysIsoRMonrSts) {
case 0:
content += String("Not valid 1");
break;
case 1:
content += String("False");
break;
case 2:
content += String("True");
break;
case 3:
content += String("Not valid 2");
break;
default:
content += String("Not valid");
}
return content;
}
};
#endif