mirror of
https://github.com/dalathegreat/Battery-Emulator.git
synced 2025-10-05 10:49:42 +02:00
Merge pull request #1093 from dalathegreat/bugfix/volvo-spa-limits
Volvo SPA: Tweak voltage limits for 96S battery
This commit is contained in:
commit
7237f1b68b
1 changed files with 3 additions and 3 deletions
|
@ -6,11 +6,11 @@
|
|||
#define BATTERY_SELECTED
|
||||
#define MAX_PACK_VOLTAGE_108S_DV 4540
|
||||
#define MIN_PACK_VOLTAGE_108S_DV 2938
|
||||
#define MAX_PACK_VOLTAGE_96S_DV 4030
|
||||
#define MAX_PACK_VOLTAGE_96S_DV 4080
|
||||
#define MIN_PACK_VOLTAGE_96S_DV 2620
|
||||
#define MAX_CELL_DEVIATION_MV 250
|
||||
#define MAX_CELL_VOLTAGE_MV 4210 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 2700 //Battery is put into emergency stop if one cell goes below this value
|
||||
#define MAX_CELL_VOLTAGE_MV 4260 // Charging is halted if one cell goes above this
|
||||
#define MIN_CELL_VOLTAGE_MV 2700 // Charging is halted if one cell goes below this
|
||||
|
||||
void setup_battery(void);
|
||||
void transmit_can_frame(CAN_frame* tx_frame, int interface);
|
||||
|
|