Merge pull request #1161 from dalathegreat/bugfix/ferroamp-total-cell-amount

Ferroamp: Bugfix, Now possible to set TOTAL_CELL_AMOUNT over 255
This commit is contained in:
Daniel Öster 2025-05-23 14:46:48 +03:00 committed by GitHub
commit 7c0e6fabc5
No known key found for this signature in database
GPG key ID: B5690EEEBB952194

View file

@ -49,14 +49,14 @@ Change the following only if your inverter is generating fault codes about volta
.ext_ID = true,
.DLC = 8,
.ID = 0x7320,
.data = {TOTAL_CELL_AMOUNT, (uint8_t)(TOTAL_CELL_AMOUNT >> 8), MODULES_IN_SERIES,
.data = {(TOTAL_CELL_AMOUNT & 0xFF), (uint8_t)(TOTAL_CELL_AMOUNT >> 8), MODULES_IN_SERIES,
CELLS_PER_MODULE, (uint8_t)(VOLTAGE_LEVEL & 0x00FF), (uint8_t)(VOLTAGE_LEVEL >> 8),
AH_CAPACITY, (uint8_t)(AH_CAPACITY >> 8)}};
CAN_frame PYLON_7321 = {.FD = false,
.ext_ID = true,
.DLC = 8,
.ID = 0x7321,
.data = {TOTAL_CELL_AMOUNT, (uint8_t)(TOTAL_CELL_AMOUNT >> 8), MODULES_IN_SERIES,
.data = {(TOTAL_CELL_AMOUNT & 0xFF), (uint8_t)(TOTAL_CELL_AMOUNT >> 8), MODULES_IN_SERIES,
CELLS_PER_MODULE, (uint8_t)(VOLTAGE_LEVEL & 0x00FF), (uint8_t)(VOLTAGE_LEVEL >> 8),
AH_CAPACITY, (uint8_t)(AH_CAPACITY >> 8)}};
CAN_frame PYLON_4210 = {.FD = false,