Wrap digitalwrite and PWMwrite in own function
This commit is contained in:
parent
59a58f45c9
commit
7f16ee6fb0
2 changed files with 56 additions and 50 deletions
|
@ -120,6 +120,16 @@ MyTimer check_pause_2s(INTERVAL_2_S);
|
|||
enum State { DISCONNECTED, PRECHARGE, NEGATIVE, POSITIVE, PRECHARGE_OFF, COMPLETED, SHUTDOWN_REQUESTED };
|
||||
State contactorStatus = DISCONNECTED;
|
||||
|
||||
#define ON 1
|
||||
#define OFF 0
|
||||
|
||||
#ifdef NC_CONTACTORS //Normally closed contactors use inverted logic
|
||||
#undef ON
|
||||
#define ON 0
|
||||
#undef OFF
|
||||
#define OFF 1
|
||||
#endif
|
||||
|
||||
#define MAX_ALLOWED_FAULT_TICKS 1000
|
||||
/* NOTE: modify the precharge time constant below to account for the resistance and capacitance of the target system.
|
||||
* t=3RC at minimum, t=5RC ideally
|
||||
|
@ -127,20 +137,34 @@ State contactorStatus = DISCONNECTED;
|
|||
#define PRECHARGE_TIME_MS 160
|
||||
#define NEGATIVE_CONTACTOR_TIME_MS 1000
|
||||
#define POSITIVE_CONTACTOR_TIME_MS 2000
|
||||
#ifdef PWM_CONTACTOR_CONTROL
|
||||
#define PWM_Freq 20000 // 20 kHz frequency, beyond audible range
|
||||
#define PWM_Res 10 // 10 Bit resolution 0 to 1023, maps 'nicely' to 0% 100%
|
||||
#define PWM_Hold_Duty 250
|
||||
#define PWM_Off_Duty 0
|
||||
#define PWM_On_Duty 1023
|
||||
#define PWM_HOLD_DUTY 250
|
||||
#define PWM_OFF_DUTY 0
|
||||
#define PWM_ON_DUTY 1023
|
||||
#define POSITIVE_PWM_Ch 0
|
||||
#define NEGATIVE_PWM_Ch 1
|
||||
#endif
|
||||
unsigned long prechargeStartTime = 0;
|
||||
unsigned long negativeStartTime = 0;
|
||||
unsigned long timeSpentInFaultedMode = 0;
|
||||
#endif
|
||||
|
||||
void set(uint8_t pin, bool direction, uint32_t pwm_freq = 0xFFFFFFFFFF){
|
||||
#ifdef PWM_CONTACTOR_CONTROL
|
||||
if(pwm_freq != 0xFFFFFFFFFF)
|
||||
{
|
||||
ledcWrite(pin, pwm_freq);
|
||||
return;
|
||||
}
|
||||
#endif
|
||||
if(direction == 1){
|
||||
digitalWrite(pin, HIGH);
|
||||
}
|
||||
else{ // 0
|
||||
digitalWrite(pin, LOW);
|
||||
}
|
||||
}
|
||||
|
||||
#ifdef EQUIPMENT_STOP_BUTTON
|
||||
const unsigned long equipment_button_long_press_duration =
|
||||
15000; // 15 seconds for long press in case of MOMENTARY_SWITCH
|
||||
|
@ -497,27 +521,27 @@ void init_CAN() {
|
|||
void init_contactors() {
|
||||
// Init contactor pins
|
||||
#ifdef CONTACTOR_CONTROL
|
||||
#ifndef PWM_CONTACTOR_CONTROL
|
||||
pinMode(POSITIVE_CONTACTOR_PIN, OUTPUT);
|
||||
digitalWrite(POSITIVE_CONTACTOR_PIN, LOW);
|
||||
pinMode(NEGATIVE_CONTACTOR_PIN, OUTPUT);
|
||||
digitalWrite(NEGATIVE_CONTACTOR_PIN, LOW);
|
||||
#else
|
||||
#ifdef PWM_CONTACTOR_CONTROL
|
||||
ledcAttachChannel(POSITIVE_CONTACTOR_PIN, PWM_Freq, PWM_Res,
|
||||
POSITIVE_PWM_Ch); // Setup PWM Channel Frequency and Resolution
|
||||
ledcAttachChannel(NEGATIVE_CONTACTOR_PIN, PWM_Freq, PWM_Res,
|
||||
NEGATIVE_PWM_Ch); // Setup PWM Channel Frequency and Resolution
|
||||
ledcWrite(POSITIVE_CONTACTOR_PIN, PWM_Off_Duty); // Set Positive PWM to 0%
|
||||
ledcWrite(NEGATIVE_CONTACTOR_PIN, PWM_Off_Duty); // Set Negative PWM to 0%
|
||||
ledcWrite(POSITIVE_CONTACTOR_PIN, PWM_OFF_DUTY); // Set Positive PWM to 0%
|
||||
ledcWrite(NEGATIVE_CONTACTOR_PIN, PWM_OFF_DUTY); // Set Negative PWM to 0%
|
||||
#else //Normal CONTACTOR_CONTROL
|
||||
pinMode(POSITIVE_CONTACTOR_PIN, OUTPUT);
|
||||
set(POSITIVE_CONTACTOR_PIN, OFF);
|
||||
pinMode(NEGATIVE_CONTACTOR_PIN, OUTPUT);
|
||||
set(NEGATIVE_CONTACTOR_PIN, OFF);
|
||||
#endif
|
||||
pinMode(PRECHARGE_PIN, OUTPUT);
|
||||
digitalWrite(PRECHARGE_PIN, LOW);
|
||||
#endif
|
||||
set(PRECHARGE_PIN, OFF);
|
||||
#endif //CONTACTOR_CONTROL
|
||||
// Init BMS contactor
|
||||
#ifdef HW_STARK // TODO: Rewrite this so LilyGo can also handle this BMS contactor
|
||||
pinMode(BMS_POWER, OUTPUT);
|
||||
digitalWrite(BMS_POWER, HIGH);
|
||||
#endif
|
||||
set(BMS_POWER, ON);
|
||||
#endif //HW_STARK
|
||||
}
|
||||
|
||||
void init_rs485() {
|
||||
|
@ -751,14 +775,9 @@ void handle_contactors() {
|
|||
contactorStatus = DISCONNECTED;
|
||||
}
|
||||
if (contactorStatus == SHUTDOWN_REQUESTED) {
|
||||
digitalWrite(PRECHARGE_PIN, LOW);
|
||||
#ifndef PWM_CONTACTOR_CONTROL
|
||||
digitalWrite(NEGATIVE_CONTACTOR_PIN, LOW);
|
||||
digitalWrite(POSITIVE_CONTACTOR_PIN, LOW);
|
||||
#else
|
||||
ledcWrite(NEGATIVE_CONTACTOR_PIN, PWM_Off_Duty);
|
||||
ledcWrite(POSITIVE_CONTACTOR_PIN, PWM_Off_Duty);
|
||||
#endif
|
||||
set(PRECHARGE_PIN, OFF);
|
||||
set(NEGATIVE_CONTACTOR_PIN, OFF, PWM_OFF_DUTY);
|
||||
set(POSITIVE_CONTACTOR_PIN, OFF, PWM_OFF_DUTY);
|
||||
set_event(EVENT_ERROR_OPEN_CONTACTOR, 0);
|
||||
datalayer.system.status.contactor_control_closed = false;
|
||||
return; // A fault scenario latches the contactor control. It is not possible to recover without a powercycle (and investigation why fault occured)
|
||||
|
@ -766,14 +785,9 @@ void handle_contactors() {
|
|||
|
||||
// After that, check if we are OK to start turning on the battery
|
||||
if (contactorStatus == DISCONNECTED) {
|
||||
digitalWrite(PRECHARGE_PIN, LOW);
|
||||
#ifndef PWM_CONTACTOR_CONTROL
|
||||
digitalWrite(NEGATIVE_CONTACTOR_PIN, LOW);
|
||||
digitalWrite(POSITIVE_CONTACTOR_PIN, LOW);
|
||||
#else
|
||||
ledcWrite(NEGATIVE_CONTACTOR_PIN, PWM_Off_Duty);
|
||||
ledcWrite(POSITIVE_CONTACTOR_PIN, PWM_Off_Duty);
|
||||
#endif
|
||||
set(PRECHARGE_PIN, OFF);
|
||||
set(NEGATIVE_CONTACTOR_PIN, OFF, PWM_OFF_DUTY);
|
||||
set(POSITIVE_CONTACTOR_PIN, OFF, PWM_OFF_DUTY);
|
||||
|
||||
if (datalayer.system.status.battery_allows_contactor_closing &&
|
||||
datalayer.system.status.inverter_allows_contactor_closing) {
|
||||
|
@ -783,8 +797,9 @@ void handle_contactors() {
|
|||
|
||||
// In case the inverter requests contactors to open, set the state accordingly
|
||||
if (contactorStatus == COMPLETED) {
|
||||
if (!datalayer.system.status.inverter_allows_contactor_closing)
|
||||
if (!datalayer.system.status.inverter_allows_contactor_closing){
|
||||
contactorStatus = DISCONNECTED;
|
||||
}
|
||||
// Skip running the state machine below if it has already completed
|
||||
return;
|
||||
}
|
||||
|
@ -793,18 +808,14 @@ void handle_contactors() {
|
|||
// Handle actual state machine. This first turns on Precharge, then Negative, then Positive, and finally turns OFF precharge
|
||||
switch (contactorStatus) {
|
||||
case PRECHARGE:
|
||||
digitalWrite(PRECHARGE_PIN, HIGH);
|
||||
set(PRECHARGE_PIN, ON);
|
||||
prechargeStartTime = currentTime;
|
||||
contactorStatus = NEGATIVE;
|
||||
break;
|
||||
|
||||
case NEGATIVE:
|
||||
if (currentTime - prechargeStartTime >= PRECHARGE_TIME_MS) {
|
||||
#ifndef PWM_CONTACTOR_CONTROL
|
||||
digitalWrite(NEGATIVE_CONTACTOR_PIN, HIGH);
|
||||
#else
|
||||
ledcWrite(NEGATIVE_CONTACTOR_PIN, PWM_On_Duty);
|
||||
#endif
|
||||
set(NEGATIVE_CONTACTOR_PIN, ON, PWM_ON_DUTY);
|
||||
negativeStartTime = currentTime;
|
||||
contactorStatus = POSITIVE;
|
||||
}
|
||||
|
@ -812,22 +823,16 @@ void handle_contactors() {
|
|||
|
||||
case POSITIVE:
|
||||
if (currentTime - negativeStartTime >= NEGATIVE_CONTACTOR_TIME_MS) {
|
||||
#ifndef PWM_CONTACTOR_CONTROL
|
||||
digitalWrite(POSITIVE_CONTACTOR_PIN, HIGH);
|
||||
#else
|
||||
ledcWrite(POSITIVE_CONTACTOR_PIN, PWM_On_Duty);
|
||||
#endif
|
||||
set(POSITIVE_CONTACTOR_PIN, ON, PWM_ON_DUTY);
|
||||
contactorStatus = PRECHARGE_OFF;
|
||||
}
|
||||
break;
|
||||
|
||||
case PRECHARGE_OFF:
|
||||
if (currentTime - negativeStartTime >= POSITIVE_CONTACTOR_TIME_MS) {
|
||||
digitalWrite(PRECHARGE_PIN, LOW);
|
||||
#ifdef PWM_CONTACTOR_CONTROL
|
||||
ledcWrite(NEGATIVE_CONTACTOR_PIN, PWM_Hold_Duty);
|
||||
ledcWrite(POSITIVE_CONTACTOR_PIN, PWM_Hold_Duty);
|
||||
#endif
|
||||
set(PRECHARGE_PIN, OFF);
|
||||
set(NEGATIVE_CONTACTOR_PIN, PWM_HOLD_DUTY);
|
||||
set(POSITIVE_CONTACTOR_PIN, PWM_HOLD_DUTY);
|
||||
contactorStatus = COMPLETED;
|
||||
datalayer.system.status.contactor_control_closed = true;
|
||||
}
|
||||
|
|
|
@ -59,6 +59,7 @@
|
|||
//#define INTERLOCK_REQUIRED //Nissan LEAF specific setting, if enabled requires both high voltage conenctors to be seated before starting
|
||||
//#define CONTACTOR_CONTROL //Enable this line to have pins 25,32,33 handle automatic precharge/contactor+/contactor- closing sequence
|
||||
//#define PWM_CONTACTOR_CONTROL //Enable this line to use PWM for CONTACTOR_CONTROL, which lowers power consumption and heat generation. CONTACTOR_CONTROL must be enabled.
|
||||
//#define NC_CONTACTORS //Enable this line to control normally closed contactors. CONTACTOR_CONTROL must be enabled for this option. Extremely rare setting!
|
||||
//#define DUAL_CAN //Enable this line to activate an isolated secondary CAN Bus using add-on MCP2515 chip (Needed for some inverters / double battery)
|
||||
#define CRYSTAL_FREQUENCY_MHZ 8 //DUAL_CAN option, what is your MCP2515 add-on boards crystal frequency?
|
||||
//#define CAN_FD //Enable this line to activate an isolated secondary CAN-FD bus using add-on MCP2518FD chip / Native CANFD on Stark board
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue