Add estimated charge/discharge values

This commit is contained in:
Daniel 2024-01-17 16:48:05 +02:00
parent 5d40e5a986
commit 8204676c9d
2 changed files with 15 additions and 3 deletions

View file

@ -168,9 +168,19 @@ void update_values_kiaHyundai_64_battery() { //This function maps all the value
remaining_capacity_Wh = static_cast<int>((static_cast<double>(SOC) / 10000) * BATTERY_WH_MAX);
max_target_discharge_power = (uint16_t)allowedDischargePower * 10; //From kW*100 to Watts
max_target_charge_power = (uint16_t)allowedChargePower * 10; //From kW*100 to Watts
//max_target_charge_power = (uint16_t)allowedChargePower * 10; //From kW*100 to Watts
//The allowed charge power is not available. We estimate this value
if (SOC == 10000) { // When scaled SOC is 100%, set allowed charge power to 0
max_target_charge_power = 0;
} else { // No limits, max charging power allowed
max_target_charge_power = MAXCHARGEPOWERALLOWED;
}
//max_target_discharge_power = (uint16_t)allowedDischargePower * 10; //From kW*100 to Watts
if (SOC < 100) { // When scaled SOC is <1%, set allowed charge power to 0
max_target_discharge_power = 0;
} else { // No limits, max charging power allowed
max_target_discharge_power = MAXDISCHARGEPOWERALLOWED;
}
powerWatt = ((batteryVoltage * batteryAmps) / 100);

View file

@ -8,6 +8,8 @@
#define ABSOLUTE_MAX_VOLTAGE \
4040 // 404.4V,if battery voltage goes over this, charging is not possible (goes into forced discharge)
#define ABSOLUTE_MIN_VOLTAGE 3100 // 310.0V if battery voltage goes under this, discharging further is disabled
#define MAXCHARGEPOWERALLOWED 10000
#define MAXDISCHARGEPOWERALLOWED 10000
// These parameters need to be mapped for the Gen24
extern uint16_t SOC; //SOC%, 0-100.00 (0-10000)