Make SPA use BMS allowed charge/discharge values

This commit is contained in:
Daniel Öster 2025-01-04 21:52:56 +02:00
parent 49d5f572e5
commit 8c8fddd32b

View file

@ -150,9 +150,8 @@ void update_values_battery() { //This function maps all the values fetched via
datalayer.battery.status.current_dA = BATT_I * 10;
datalayer.battery.status.remaining_capacity_Wh = remaining_capacity;
//datalayer.battery.status.max_discharge_power_W = HvBattPwrLimDchaSoft * 1000; // Use power limit reported from BMS, not trusted ATM
datalayer.battery.status.max_discharge_power_W = 30000;
datalayer.battery.status.max_charge_power_W = 30000;
datalayer.battery.status.max_discharge_power_W = HvBattPwrLimDchaSlowAgi * 1000; //kW to W
datalayer.battery.status.max_charge_power_W = HvBattPwrLimChrgSlowAgi * 1000; //kW to W
datalayer.battery.status.temperature_min_dC = BATT_T_MIN;
datalayer.battery.status.temperature_max_dC = BATT_T_MAX;