mirror of
https://github.com/dalathegreat/Battery-Emulator.git
synced 2025-10-05 19:42:08 +02:00
Add HVIL detection and Event
This commit is contained in:
parent
6e6e4908ad
commit
99f78dadfb
1 changed files with 13 additions and 2 deletions
|
@ -193,6 +193,7 @@ static unsigned long previousMillis50 = 0; // will store last time a 50ms CAN
|
|||
static unsigned long previousMillis100 = 0; // will store last time a 100ms CAN Message was sent
|
||||
|
||||
static uint16_t battery_voltage = 3700;
|
||||
static uint8_t HVIL_signal = 0;
|
||||
|
||||
void update_values_battery() { //This function maps all the values fetched via CAN to the correct parameters used for modbus
|
||||
datalayer.battery.status.soh_pptt;
|
||||
|
@ -218,6 +219,12 @@ void update_values_battery() { //This function maps all the values fetched via
|
|||
datalayer.battery.status.cell_min_voltage_mV;
|
||||
|
||||
datalayer.battery.status.cell_max_voltage_mV;
|
||||
|
||||
if (HVIL_signal > 0) {
|
||||
set_event(EVENT_HVIL_FAILURE, HVIL_signal);
|
||||
} else {
|
||||
clear_event(EVENT_HVIL_FAILURE);
|
||||
}
|
||||
}
|
||||
|
||||
void handle_incoming_can_frame_battery(CAN_frame rx_frame) {
|
||||
|
@ -226,6 +233,10 @@ void handle_incoming_can_frame_battery(CAN_frame rx_frame) {
|
|||
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
|
||||
//Contains:
|
||||
//HVIL Signal
|
||||
// - HVIL not connected: 000000B0 00 8 10 06 00 00 00 00 8E 31
|
||||
// - HVIL connected: 000000B0 00 8 10 00 00 00 00 00 82 0D
|
||||
// Based on this, the two HVIL is most likely frame1
|
||||
HVIL_signal = (rx_frame.data.u8[1] & 0x0F);
|
||||
//BatteryDchgSysFaultLevel
|
||||
//ChgFaultLevel
|
||||
//frame7, CRC
|
||||
|
@ -242,8 +253,8 @@ void handle_incoming_can_frame_battery(CAN_frame rx_frame) {
|
|||
case 0x17A: //100ms
|
||||
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
|
||||
break;
|
||||
case 0x17B: //20ms
|
||||
battery_voltage = ((rx_frame.data.u8[4] & 0x0F) << 8) | rx_frame.data.u8[5]; //TODO: NOT CONFIRMED
|
||||
case 0x17B: //20ms
|
||||
battery_voltage = ((rx_frame.data.u8[4] & 0x0F) << 8) | rx_frame.data.u8[5]; //TODO: NOT CONFIRMED
|
||||
datalayer.battery.status.CAN_battery_still_alive = CAN_STILL_ALIVE;
|
||||
break;
|
||||
case 0x210: //100ms
|
||||
|
|
Loading…