Merge pull request #322 from dalathegreat/feature/modbus-write-event
BYD Modbus: Tweak trigger logic for missing inverter event
This commit is contained in:
commit
a3af265ff1
1 changed files with 16 additions and 6 deletions
|
@ -6,14 +6,16 @@
|
|||
|
||||
// For modbus register definitions, see https://gitlab.com/pelle8/inverter_resources/-/blob/main/byd_registers_modbus_rtu.md
|
||||
|
||||
#define HISTORY_LENGTH 3 // Amount of samples(minutes) that needs to match for register to be considered stale
|
||||
static unsigned long previousMillis60s = 0; // will store last time a 60s event occured
|
||||
static uint32_t previous_value_register_401 = 0x0F0F;
|
||||
static uint32_t current_value_register_401 = 0xF0F0;
|
||||
static uint32_t user_configured_max_discharge_W = 0;
|
||||
static uint32_t user_configured_max_charge_W = 0;
|
||||
static uint32_t max_discharge_W = 0;
|
||||
static uint32_t max_charge_W = 0;
|
||||
static uint16_t register_401_history[HISTORY_LENGTH] = {0};
|
||||
static uint8_t history_index = 0;
|
||||
static uint8_t bms_char_dis_status = STANDBY;
|
||||
static bool all_401_values_equal = false;
|
||||
|
||||
void update_modbus_registers_inverter() {
|
||||
verify_temperature_modbus();
|
||||
|
@ -115,21 +117,29 @@ void verify_temperature_modbus() {
|
|||
|
||||
void verify_inverter_modbus() {
|
||||
// Every 60 seconds, the Gen24 writes to this 401 register, alternating between 00FF and FF00.
|
||||
// We use this info to see if inverter is still alive, incase not, raise an event
|
||||
// We sample the register every 60 seconds. Incase the value has not changed for 3 minutes, we raise an event
|
||||
unsigned long currentMillis = millis();
|
||||
|
||||
if (currentMillis - previousMillis60s >= INTERVAL_60_S) {
|
||||
previousMillis60s = currentMillis;
|
||||
|
||||
current_value_register_401 = mbPV[401];
|
||||
all_401_values_equal = true;
|
||||
for (int i = 0; i < HISTORY_LENGTH; ++i) {
|
||||
if (register_401_history[i] != mbPV[401]) {
|
||||
all_401_values_equal = false;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
if (current_value_register_401 == previous_value_register_401) {
|
||||
if (all_401_values_equal) {
|
||||
set_event(EVENT_MODBUS_INVERTER_MISSING, 0);
|
||||
} else {
|
||||
clear_event(EVENT_MODBUS_INVERTER_MISSING);
|
||||
}
|
||||
|
||||
previous_value_register_401 = current_value_register_401;
|
||||
// Update history
|
||||
register_401_history[history_index] = mbPV[401];
|
||||
history_index = (history_index + 1) % HISTORY_LENGTH;
|
||||
}
|
||||
}
|
||||
#endif
|
||||
|
|