Add Event when automatic contactor opening happens
This commit is contained in:
parent
a209fb92e7
commit
b141161d9a
3 changed files with 8 additions and 2 deletions
|
@ -147,6 +147,7 @@ void init_events(void) {
|
|||
events.entries[EVENT_PRECHARGE_FAILURE].level = EVENT_LEVEL_INFO;
|
||||
events.entries[EVENT_INTERNAL_OPEN_FAULT].level = EVENT_LEVEL_ERROR;
|
||||
events.entries[EVENT_INVERTER_OPEN_CONTACTOR].level = EVENT_LEVEL_INFO;
|
||||
events.entries[EVENT_ERROR_OPEN_CONTACTOR].level = EVENT_LEVEL_INFO;
|
||||
events.entries[EVENT_CELL_UNDER_VOLTAGE].level = EVENT_LEVEL_ERROR;
|
||||
events.entries[EVENT_CELL_OVER_VOLTAGE].level = EVENT_LEVEL_ERROR;
|
||||
events.entries[EVENT_CELL_DEVIATION_HIGH].level = EVENT_LEVEL_WARNING;
|
||||
|
@ -237,6 +238,9 @@ const char* get_event_message_string(EVENTS_ENUM_TYPE event) {
|
|||
return "ERROR: High voltage cable removed while battery running. Opening contactors!";
|
||||
case EVENT_INVERTER_OPEN_CONTACTOR:
|
||||
return "Info: Inverter side opened contactors. Normal operation.";
|
||||
case EVENT_ERROR_OPEN_CONTACTOR:
|
||||
return "Info: Too much time spent in error state. Opening contactors, not safe to continue charging. "
|
||||
"Check other error code for reason!";
|
||||
case EVENT_CELL_UNDER_VOLTAGE:
|
||||
return "ERROR: CELL UNDERVOLTAGE!!! Stopping battery charging and discharging. Inspect battery!";
|
||||
case EVENT_CELL_OVER_VOLTAGE:
|
||||
|
|