Tigthen cellvoltage warnings on batteries
This commit is contained in:
parent
fee857f2ab
commit
b3b5f9299c
10 changed files with 14 additions and 15 deletions
|
@ -7,7 +7,7 @@
|
|||
|
||||
#define MAX_PACK_VOLTAGE_DV 4150 //5000 = 500.0V
|
||||
#define MIN_PACK_VOLTAGE_DV 2500
|
||||
#define MAX_CELL_DEVIATION_MV 500
|
||||
#define MAX_CELL_DEVIATION_MV 150
|
||||
#define MAX_CELL_VOLTAGE_MV 4250 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 2700 //Battery is put into emergency stop if one cell goes below this value
|
||||
|
||||
|
|
|
@ -6,7 +6,7 @@
|
|||
#define BATTERY_SELECTED
|
||||
#define MAX_PACK_VOLTAGE_DV 3696 //5000 = 500.0V
|
||||
#define MIN_PACK_VOLTAGE_DV 3160
|
||||
#define MAX_CELL_DEVIATION_MV 500
|
||||
#define MAX_CELL_DEVIATION_MV 250
|
||||
#define MAX_CELL_VOLTAGE_MV 4150 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 2750 //Battery is put into emergency stop if one cell goes below this value
|
||||
|
||||
|
|
|
@ -5,7 +5,7 @@
|
|||
#define BATTERY_SELECTED
|
||||
#define MAX_PACK_VOLTAGE_DV 4546 //5000 = 500.0V
|
||||
#define MIN_PACK_VOLTAGE_DV 3370
|
||||
#define MAX_CELL_DEVIATION_MV 500
|
||||
#define MAX_CELL_DEVIATION_MV 250
|
||||
#define MAX_CELL_VOLTAGE_MV 4250 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 2700 //Battery is put into emergency stop if one cell goes below this value
|
||||
|
||||
|
|
|
@ -6,7 +6,7 @@
|
|||
#define BATTERY_SELECTED
|
||||
#define MAX_PACK_VOLTAGE_DV 4040 //5000 = 500.0V
|
||||
#define MIN_PACK_VOLTAGE_DV 2600
|
||||
#define MAX_CELL_DEVIATION_MV 500
|
||||
#define MAX_CELL_DEVIATION_MV 150
|
||||
#define MAX_CELL_VOLTAGE_MV 4250 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 2700 //Battery is put into emergency stop if one cell goes below this value
|
||||
|
||||
|
|
|
@ -10,7 +10,7 @@
|
|||
#define MIN_PACK_VOLTAGE_DV 1500
|
||||
#define MAX_CELL_VOLTAGE_MV 4250 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 2700 //Battery is put into emergency stop if one cell goes below this value
|
||||
#define MAX_CELL_DEVIATION_MV 500
|
||||
#define MAX_CELL_DEVIATION_MV 150
|
||||
|
||||
void setup_battery(void);
|
||||
void transmit_can_frame(CAN_frame* tx_frame, int interface);
|
||||
|
|
|
@ -10,7 +10,7 @@
|
|||
#define MIN_PACK_VOLTAGE_DV 0 //TODO: Configure
|
||||
#define MAX_CELL_VOLTAGE_MV 4250 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 2700 //Battery is put into emergency stop if one cell goes below this value
|
||||
#define MAX_CELL_DEVIATION_MV 500 //TODO: Configure
|
||||
#define MAX_CELL_DEVIATION_MV 150
|
||||
|
||||
void setup_battery(void);
|
||||
void transmit_can_frame(CAN_frame* tx_frame, int interface);
|
||||
|
|
|
@ -6,7 +6,7 @@
|
|||
#define BATTERY_SELECTED
|
||||
#define MAX_PACK_VOLTAGE_DV 4150 //5000 = 500.0V
|
||||
#define MIN_PACK_VOLTAGE_DV 2500
|
||||
#define MAX_CELL_DEVIATION_MV 500
|
||||
#define MAX_CELL_DEVIATION_MV 150
|
||||
#define MAX_CELL_VOLTAGE_MV 4250 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 2700 //Battery is put into emergency stop if one cell goes below this value
|
||||
#define MAX_CHARGE_POWER_W 5000 // Battery can be charged with this amount of power
|
||||
|
|
|
@ -5,7 +5,7 @@
|
|||
#define BATTERY_SELECTED
|
||||
#define MAX_PACK_VOLTAGE_DV 579 // 57.9V at 100% SOC (with 70% SOH, new one might be higher)
|
||||
#define MIN_PACK_VOLTAGE_DV 480 // 48.4V at 13.76% SOC
|
||||
#define MAX_CELL_DEVIATION_MV 500
|
||||
#define MAX_CELL_DEVIATION_MV 150
|
||||
#define MAX_CELL_VOLTAGE_MV 4200 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 3400 //Battery is put into emergency stop if one cell goes below this value
|
||||
|
||||
|
|
|
@ -3,10 +3,9 @@
|
|||
#include "../include.h"
|
||||
|
||||
#define BATTERY_SELECTED
|
||||
#define MAX_CELL_DEVIATION_MV 500
|
||||
#define MAX_PACK_VOLTAGE_DV 4200 //5000 = 500.0V
|
||||
#define MIN_PACK_VOLTAGE_DV 3000
|
||||
#define MAX_CELL_DEVIATION_MV 500
|
||||
#define MAX_CELL_DEVIATION_MV 150
|
||||
#define MAX_CELL_VOLTAGE_MV 4250 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 2700 //Battery is put into emergency stop if one cell goes below this value
|
||||
|
||||
|
|
|
@ -5,7 +5,7 @@
|
|||
#define BATTERY_SELECTED
|
||||
#define MAX_PACK_VOLTAGE_DV 4100 //5000 = 500.0V
|
||||
#define MIN_PACK_VOLTAGE_DV 3000
|
||||
#define MAX_CELL_DEVIATION_MV 500
|
||||
#define MAX_CELL_DEVIATION_MV 150
|
||||
#define MAX_CELL_VOLTAGE_MV 4250 //Battery is put into emergency stop if one cell goes over this value
|
||||
#define MIN_CELL_VOLTAGE_MV 2700 //Battery is put into emergency stop if one cell goes below this value
|
||||
|
||||
|
|
Loading…