Make SOC missing warning with more info

This commit is contained in:
Daniel Öster 2024-09-16 15:13:15 +03:00
parent 5aec27eb5b
commit db455caaf2
3 changed files with 7 additions and 3 deletions

View file

@ -145,6 +145,7 @@ void init_events(void) {
events.entries[EVENT_DISCHARGE_LIMIT_EXCEEDED].level = EVENT_LEVEL_INFO;
events.entries[EVENT_12V_LOW].level = EVENT_LEVEL_WARNING;
events.entries[EVENT_SOC_PLAUSIBILITY_ERROR].level = EVENT_LEVEL_ERROR;
events.entries[EVENT_SOC_UNAVAILABLE].level = EVENT_LEVEL_WARNING;
events.entries[EVENT_KWH_PLAUSIBILITY_ERROR].level = EVENT_LEVEL_INFO;
events.entries[EVENT_BATTERY_EMPTY].level = EVENT_LEVEL_INFO;
events.entries[EVENT_BATTERY_FULL].level = EVENT_LEVEL_INFO;
@ -255,6 +256,8 @@ const char* get_event_message_string(EVENTS_ENUM_TYPE event) {
return "12V battery source below required voltage to safely close contactors. Inspect the supply/battery!";
case EVENT_SOC_PLAUSIBILITY_ERROR:
return "ERROR: SOC% reported by battery not plausible. Restart battery!";
case EVENT_SOC_UNAVAILABLE:
return "Warning: SOC% not sent by BMS. Calibrate BMS via app.";
case EVENT_KWH_PLAUSIBILITY_ERROR:
return "Info: kWh remaining reported by battery not plausible. Battery needs cycling.";
case EVENT_BATTERY_EMPTY: