@ -28,7 +28,6 @@ static int16_t current_per_pack = 0;
static uint8_t temperature_max_per_pack = 0; static uint8_t temperature_max_per_pack = 0;
static uint8_t temperature_min_per_pack = 0; static uint8_t temperature_min_per_pack = 0;
static uint8_t current_pack_info = 0; static uint8_t current_pack_info = 0;
static uint8_t inverterStillAlive = 60; // Inverter can be missing for 1minute on startup
static bool send_cellvoltages = false; static bool send_cellvoltages = false;
static unsigned long previousMillisCellvoltage = 0; // Store the last time a cellvoltage CAN messages were sent static unsigned long previousMillisCellvoltage = 0; // Store the last time a cellvoltage CAN messages were sent
@ -362,16 +361,6 @@ void update_values_can_inverter() { //This function maps all the CAN values fet
temperature_average = temperature_average =
((datalayer.battery.status.temperature_max_dC + datalayer.battery.status.temperature_min_dC) / 2); ((datalayer.battery.status.temperature_max_dC + datalayer.battery.status.temperature_min_dC) / 2);
if (inverterStillAlive > 0) {
inverterStillAlive--;
}
if (!inverterStillAlive) {
set_event(EVENT_CAN_INVERTER_MISSING, 0);
} else {
clear_event(EVENT_CAN_INVERTER_MISSING);
}
//Put the values into the CAN messages //Put the values into the CAN messages
//BMS_Limits //BMS_Limits
FOXESS_1872.data.u8[0] = (uint8_t)datalayer.battery.info.max_design_voltage_dV; FOXESS_1872.data.u8[0] = (uint8_t)datalayer.battery.info.max_design_voltage_dV;
@ -686,7 +675,7 @@ void send_can_inverter() { // This function loops as fast as possible
void receive_can_inverter(CAN_frame rx_frame) { void receive_can_inverter(CAN_frame rx_frame) {
if (rx_frame.ID == 0x1871) { if (rx_frame.ID == 0x1871) {
inverterStillAlive = CAN_STILL_ALIVE; datalayer.system.status.CAN_inverter_still_alive = CAN_STILL_ALIVE;
if (rx_frame.data.u8[0] == 0x03) { //0x1871 [0x03, 0x06, 0x17, 0x05, 0x09, 0x09, 0x28, 0x22] if (rx_frame.data.u8[0] == 0x03) { //0x1871 [0x03, 0x06, 0x17, 0x05, 0x09, 0x09, 0x28, 0x22]
//This message is sent by the inverter every '6' seconds (0.5s after the pack serial numbers) //This message is sent by the inverter every '6' seconds (0.5s after the pack serial numbers)
//and contains a timestamp in bytes 2-7 i.e. <YY>,<MM>,<DD>,<HH>,<mm>,<ss> //and contains a timestamp in bytes 2-7 i.e. <YY>,<MM>,<DD>,<HH>,<mm>,<ss>