Add Sofar fix for voltages
This commit is contained in:
parent
e93e1289fb
commit
dc84b15e2f
1 changed files with 16 additions and 0 deletions
|
@ -4,6 +4,8 @@
|
||||||
|
|
||||||
#define SEND_0 //If defined, the messages will have ID ending with 0 (useful for some inverters)
|
#define SEND_0 //If defined, the messages will have ID ending with 0 (useful for some inverters)
|
||||||
//#define SEND_1 //If defined, the messages will have ID ending with 1 (useful for some inverters)
|
//#define SEND_1 //If defined, the messages will have ID ending with 1 (useful for some inverters)
|
||||||
|
#define INVERT_VOLTAGE //If defined, the min/max voltage frames will be inverted, \
|
||||||
|
//useful for some inverters like Sofar that report the voltages incorrect otherwise
|
||||||
|
|
||||||
/* Do not change code below unless you are sure what you are doing */
|
/* Do not change code below unless you are sure what you are doing */
|
||||||
//Actual content messages
|
//Actual content messages
|
||||||
|
@ -199,6 +201,19 @@ void update_values_can_pylon() { //This function maps all the values fetched fr
|
||||||
PYLON_4210.data.u8[7] = (StateOfHealth * 0.01);
|
PYLON_4210.data.u8[7] = (StateOfHealth * 0.01);
|
||||||
PYLON_4211.data.u8[7] = (StateOfHealth * 0.01);
|
PYLON_4211.data.u8[7] = (StateOfHealth * 0.01);
|
||||||
|
|
||||||
|
#ifdef INVERT_VOLTAGE //Useful for Sofar inverters
|
||||||
|
//Minvoltage (eg 300.0V = 3000 , 16bits long) Charge Cutoff Voltage
|
||||||
|
PYLON_4220.data.u8[0] = (min_voltage & 0x00FF);
|
||||||
|
PYLON_4220.data.u8[1] = (min_voltage >> 8);
|
||||||
|
PYLON_4221.data.u8[0] = (min_voltage & 0x00FF);
|
||||||
|
PYLON_4221.data.u8[1] = (min_voltage >> 8);
|
||||||
|
|
||||||
|
//Maxvoltage (eg 400.0V = 4000 , 16bits long) Discharge Cutoff Voltage
|
||||||
|
PYLON_4220.data.u8[2] = (max_voltage & 0x00FF);
|
||||||
|
PYLON_4220.data.u8[3] = (max_voltage >> 8);
|
||||||
|
PYLON_4221.data.u8[2] = (max_voltage & 0x00FF);
|
||||||
|
PYLON_4221.data.u8[3] = (max_voltage >> 8);
|
||||||
|
#else
|
||||||
//Minvoltage (eg 300.0V = 3000 , 16bits long) Charge Cutoff Voltage
|
//Minvoltage (eg 300.0V = 3000 , 16bits long) Charge Cutoff Voltage
|
||||||
PYLON_4220.data.u8[0] = (min_voltage >> 8);
|
PYLON_4220.data.u8[0] = (min_voltage >> 8);
|
||||||
PYLON_4220.data.u8[1] = (min_voltage & 0x00FF);
|
PYLON_4220.data.u8[1] = (min_voltage & 0x00FF);
|
||||||
|
@ -210,6 +225,7 @@ void update_values_can_pylon() { //This function maps all the values fetched fr
|
||||||
PYLON_4220.data.u8[3] = (max_voltage & 0x00FF);
|
PYLON_4220.data.u8[3] = (max_voltage & 0x00FF);
|
||||||
PYLON_4221.data.u8[2] = (max_voltage >> 8);
|
PYLON_4221.data.u8[2] = (max_voltage >> 8);
|
||||||
PYLON_4221.data.u8[3] = (max_voltage & 0x00FF);
|
PYLON_4221.data.u8[3] = (max_voltage & 0x00FF);
|
||||||
|
#endif
|
||||||
|
|
||||||
//In case we run into any errors/faults, we can set charge / discharge forbidden
|
//In case we run into any errors/faults, we can set charge / discharge forbidden
|
||||||
if (bms_status == FAULT) {
|
if (bms_status == FAULT) {
|
||||||
|
|