mirror of
https://github.com/dalathegreat/Battery-Emulator.git
synced 2025-10-04 10:19:29 +02:00
Rework discharge calculation
This commit is contained in:
parent
36deffd9e9
commit
e2d3c4f023
2 changed files with 9 additions and 10 deletions
|
@ -26,7 +26,6 @@ CAN_frame_t TESLA_221_2 = {
|
|||
.MsgID = 0x221,
|
||||
.data = {0x61, 0x15, 0x01, 0x00, 0x00, 0x00, 0x20, 0xBA}}; //Contactor Frame 221 - hv_up_for_drive
|
||||
|
||||
static uint32_t temporaryvariable = 0;
|
||||
static uint32_t total_discharge = 0;
|
||||
static uint32_t total_charge = 0;
|
||||
static uint16_t volts = 0; // V
|
||||
|
@ -186,15 +185,13 @@ void update_values_tesla_model_3_battery() { //This function maps all the value
|
|||
|
||||
remaining_capacity_Wh = (expected_energy_remaining * 100); //Scale up 60.3kWh -> 60300Wh
|
||||
|
||||
//Calculate the allowed discharge power, cap it if it gets too large
|
||||
temporaryvariable = (max_discharge_current * volts);
|
||||
if (temporaryvariable > 60000) {
|
||||
max_target_discharge_power = 60000;
|
||||
} else {
|
||||
max_target_discharge_power = temporaryvariable;
|
||||
}
|
||||
if (SOC < 20) { // When battery is lower than 0.20% , set allowed discharge W to 0
|
||||
// Define the allowed discharge power
|
||||
max_target_discharge_power = (max_discharge_current * volts);
|
||||
// Cap the allowed discharge power if battery is empty, or discharge power is higher than the maximum discharge power allowed
|
||||
if (SOC == 0) {
|
||||
max_target_discharge_power = 0;
|
||||
} else if (max_target_discharge_power > MAXDISCHARGEPOWERALLOWED) {
|
||||
max_target_discharge_power = MAXDISCHARGEPOWERALLOWED;
|
||||
}
|
||||
|
||||
//The allowed charge power behaves strangely. We instead estimate this value
|
||||
|
@ -202,7 +199,7 @@ void update_values_tesla_model_3_battery() { //This function maps all the value
|
|||
max_target_charge_power = 0;
|
||||
} else if (soc_vi > 950) { // When real SOC is between 95-99.99%, ramp the value between Max<->0
|
||||
max_target_charge_power = MAXCHARGEPOWERALLOWED * (1 - (soc_vi - 950) / 50.0);
|
||||
} else { // No limits, max charging power allowed
|
||||
} else { // No limits, max charging power allowed
|
||||
max_target_charge_power = MAXCHARGEPOWERALLOWED;
|
||||
}
|
||||
|
||||
|
|
|
@ -9,6 +9,8 @@
|
|||
4030 // 403.0V,if battery voltage goes over this, charging is not possible (goes into forced discharge)
|
||||
#define ABSOLUTE_MIN_VOLTAGE 2450 // 245.0V if battery voltage goes under this, discharging further is disabled
|
||||
#define MAXCHARGEPOWERALLOWED 15000 // 15000W we use a define since the value supplied by Tesla is always 0
|
||||
#define MAXDISCHARGEPOWERALLOWED \
|
||||
60000 // 60000W we need to cap this value to max 60kW, most inverters overflow otherwise
|
||||
|
||||
// These parameters need to be mapped for the Inverter
|
||||
extern uint16_t SOC;
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue