Uncomment constantly active debug

This commit is contained in:
Daniel 2023-11-07 16:31:29 +02:00
parent 6abaedfb01
commit fafb08f9d7

View file

@ -555,11 +555,11 @@ void printFaultCodesIfActive(){
printDebugIfActive(SecondaryBmbMiaFault, "ERROR: voltage and temperature readings from secondary BMB chain are mia");
printDebugIfActive(BmbMismatchFault, "ERROR: primary and secondary BMB chain readings don't match with each other");
printDebugIfActive(BmsHviMiaFault, "ERROR: BMS node is mia on HVS or HVI CAN");
printDebugIfActive(CpMiaFault, "ERROR: CP node is mia on HVS CAN");
//printDebugIfActive(CpMiaFault, "ERROR: CP node is mia on HVS CAN"); //Uncommented due to not affecting usage
printDebugIfActive(PcsMiaFault, "ERROR: PCS node is mia on HVS CAN");
printDebugIfActive(BmsFault, "ERROR: BmsFault is active");
//printDebugIfActive(BmsFault, "ERROR: BmsFault is active"); //Uncommented due to not affecting usage
printDebugIfActive(PcsFault, "ERROR: PcsFault is active");
printDebugIfActive(CpFault, "ERROR: CpFault is active");
//printDebugIfActive(CpFault, "ERROR: CpFault is active"); //Uncommented due to not affecting usage
printDebugIfActive(ShuntHwMiaFault, "ERROR: shunt current reading is not available");
printDebugIfActive(PyroMiaFault, "ERROR: pyro squib is not connected");
printDebugIfActive(hvsMiaFault, "ERROR: pack contactor hw fault");
@ -569,7 +569,7 @@ void printFaultCodesIfActive(){
printDebugIfActive(HvilFault, "ERROR: High Voltage Inter Lock fault is detected");
printDebugIfActive(BmsHvsMiaFault, "ERROR: BMS node is mia on HVS or HVI CAN");
printDebugIfActive(PackVoltMismatchFault, "ERROR: Pack voltage doesn't match approximately with sum of brick voltages");
printDebugIfActive(EnsMiaFault, "ERROR: ENS line is not connected to HVC");
//printDebugIfActive(EnsMiaFault, "ERROR: ENS line is not connected to HVC"); //Uncommented due to not affecting usage
printDebugIfActive(PackPosCtrArcFault, "ERROR: HVP detectes series arc at pack contactor");
printDebugIfActive(packNegCtrArcFault, "ERROR: HVP detectes series arc at FC contactor");
printDebugIfActive(ShuntHwAndBmsMiaFault, "ERROR: ShuntHwAndBmsMiaFault is active");
@ -578,7 +578,7 @@ void printFaultCodesIfActive(){
printDebugIfActive(packContHwFault, "ERROR: packContHwFault is active");
printDebugIfActive(pyroFuseBlown, "ERROR: pyroFuseBlown is active");
printDebugIfActive(pyroFuseFailedToBlow, "ERROR: pyroFuseFailedToBlow is active");
printDebugIfActive(CpilFault, "ERROR: CpilFault is active");
//printDebugIfActive(CpilFault, "ERROR: CpilFault is active"); //Uncommented due to not affecting usage
printDebugIfActive(PackContactorFellOpen, "ERROR: PackContactorFellOpen is active");
printDebugIfActive(FcContactorFellOpen, "ERROR: FcContactorFellOpen is active");
printDebugIfActive(packCtrCloseBlocked, "ERROR: packCtrCloseBlocked is active");