Merge remote-tracking branch 'origin/main' into feature/automatic-precharge
This commit is contained in:
commit
fbd9fe6900
147 changed files with 15677 additions and 12777 deletions
|
@ -316,6 +316,19 @@ String advanced_battery_processor(const String& var) {
|
|||
String(falseTrue[datalayer_extended.cellpower.warning_Charger_not_responding]) + "</h4>";
|
||||
#endif //CELLPOWER_BMS
|
||||
|
||||
#ifdef KIA_HYUNDAI_64_BATTERY
|
||||
content += "<h4>Cells: " + String(datalayer_extended.KiaHyundai64.total_cell_count) + "S</h4>";
|
||||
content += "<h4>12V voltage: " + String(datalayer_extended.KiaHyundai64.battery_12V / 10.0, 1) + "</h4>";
|
||||
content += "<h4>Waterleakage: " + String(datalayer_extended.KiaHyundai64.waterleakageSensor) + "</h4>";
|
||||
content +=
|
||||
"<h4>Temperature, water inlet: " + String(datalayer_extended.KiaHyundai64.temperature_water_inlet) + "</h4>";
|
||||
content +=
|
||||
"<h4>Temperature, power relay: " + String(datalayer_extended.KiaHyundai64.powerRelayTemperature) + "</h4>";
|
||||
content += "<h4>Batterymanagement mode: " + String(datalayer_extended.KiaHyundai64.batteryManagementMode) + "</h4>";
|
||||
content += "<h4>BMS ignition: " + String(datalayer_extended.KiaHyundai64.BMS_ign) + "</h4>";
|
||||
content += "<h4>Battery relay: " + String(datalayer_extended.KiaHyundai64.batteryRelay) + "</h4>";
|
||||
#endif //KIA_HYUNDAI_64_BATTERY
|
||||
|
||||
#ifdef BYD_ATTO_3_BATTERY
|
||||
static const char* SOCmethod[2] = {"Estimated from voltage", "Measured by BMS"};
|
||||
content += "<h4>SOC method used: " + String(SOCmethod[datalayer_extended.bydAtto3.SOC_method]) + "</h4>";
|
||||
|
@ -496,6 +509,8 @@ String advanced_battery_processor(const String& var) {
|
|||
static const char* falseTrue[] = {"False", "True"};
|
||||
static const char* noYes[] = {"No", "Yes"};
|
||||
static const char* Fault[] = {"NOT_ACTIVE", "ACTIVE"};
|
||||
//Buttons for user action
|
||||
content += "<button onclick='askClearIsolation()'>Clear isolation fault</button>";
|
||||
//0x20A 522 HVP_contatorState
|
||||
content += "<h4>Contactor Status: " + String(contactorText[datalayer_extended.tesla.status_contactor]) + "</h4>";
|
||||
content += "<h4>HVIL: " + String(hvilStatusState[datalayer_extended.tesla.hvil_status]) + "</h4>";
|
||||
|
@ -1033,15 +1048,123 @@ String advanced_battery_processor(const String& var) {
|
|||
content += "<h4>soc max: " + String(datalayer_extended.zoePH2.battery_soc_max) + "</h4>";
|
||||
#endif //RENAULT_ZOE_GEN2_BATTERY
|
||||
|
||||
#ifdef VOLVO_SPA_BATTERY
|
||||
content += "<h4>BECM reported SOC: " + String(datalayer_extended.VolvoPolestar.soc_bms) + "</h4>";
|
||||
content += "<h4>Calculated SOC: " + String(datalayer_extended.VolvoPolestar.soc_calc) + "</h4>";
|
||||
content += "<h4>Rescaled SOC: " + String(datalayer_extended.VolvoPolestar.soc_rescaled / 10) + "</h4>";
|
||||
content += "<h4>BECM reported SOH: " + String(datalayer_extended.VolvoPolestar.soh_bms) + "</h4>";
|
||||
content += "<h4>BECM supply voltage: " + String(datalayer_extended.VolvoPolestar.BECMsupplyVoltage) + " mV</h4>";
|
||||
|
||||
content += "<h4>HV voltage: " + String(datalayer_extended.VolvoPolestar.BECMBatteryVoltage) + " V</h4>";
|
||||
content += "<h4>HV current: " + String(datalayer_extended.VolvoPolestar.BECMBatteryCurrent) + " A</h4>";
|
||||
content += "<h4>Dynamic max voltage: " + String(datalayer_extended.VolvoPolestar.BECMUDynMaxLim) + " V</h4>";
|
||||
content += "<h4>Dynamic min voltage: " + String(datalayer_extended.VolvoPolestar.BECMUDynMinLim) + " V</h4>";
|
||||
|
||||
content +=
|
||||
"<h4>Discharge power limit 1: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimDcha1) + " kW</h4>";
|
||||
content +=
|
||||
"<h4>Discharge soft power limit: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimDchaSoft) + " kW</h4>";
|
||||
content +=
|
||||
"<h4>Discharge power limit slow aging: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimDchaSlowAgi) +
|
||||
" kW</h4>";
|
||||
content +=
|
||||
"<h4>Charge power limit slow aging: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimChrgSlowAgi) +
|
||||
" kW</h4>";
|
||||
|
||||
content += "<h4>HV system relay status: ";
|
||||
switch (datalayer_extended.VolvoPolestar.HVSysRlySts) {
|
||||
case 0:
|
||||
content += String("Open");
|
||||
break;
|
||||
case 1:
|
||||
content += String("Closed");
|
||||
break;
|
||||
case 2:
|
||||
content += String("KeepStatus");
|
||||
break;
|
||||
case 3:
|
||||
content += String("OpenAndRequestActiveDischarge");
|
||||
break;
|
||||
default:
|
||||
content += String("Not valid");
|
||||
}
|
||||
content += "</h4><h4>HV system relay status 1: ";
|
||||
switch (datalayer_extended.VolvoPolestar.HVSysDCRlySts1) {
|
||||
case 0:
|
||||
content += String("Open");
|
||||
break;
|
||||
case 1:
|
||||
content += String("Closed");
|
||||
break;
|
||||
case 2:
|
||||
content += String("KeepStatus");
|
||||
break;
|
||||
case 3:
|
||||
content += String("Fault");
|
||||
break;
|
||||
default:
|
||||
content += String("Not valid");
|
||||
}
|
||||
content += "</h4><h4>HV system relay status 2: ";
|
||||
switch (datalayer_extended.VolvoPolestar.HVSysDCRlySts2) {
|
||||
case 0:
|
||||
content += String("Open");
|
||||
break;
|
||||
case 1:
|
||||
content += String("Closed");
|
||||
break;
|
||||
case 2:
|
||||
content += String("KeepStatus");
|
||||
break;
|
||||
case 3:
|
||||
content += String("Fault");
|
||||
break;
|
||||
default:
|
||||
content += String("Not valid");
|
||||
}
|
||||
content += "</h4><h4>HV system isolation resistance monitoring status: ";
|
||||
switch (datalayer_extended.VolvoPolestar.HVSysIsoRMonrSts) {
|
||||
case 0:
|
||||
content += String("Not valid 1");
|
||||
break;
|
||||
case 1:
|
||||
content += String("False");
|
||||
break;
|
||||
case 2:
|
||||
content += String("True");
|
||||
break;
|
||||
case 3:
|
||||
content += String("Not valid 2");
|
||||
break;
|
||||
default:
|
||||
content += String("Not valid");
|
||||
}
|
||||
|
||||
content += "<br><br><button onclick='Volvo_askEraseDTC()'>Erase DTC</button><br>";
|
||||
content += "<button onclick='Volvo_askReadDTC()'>Read DTC (result must be checked in CANlog)</button><br>";
|
||||
content += "<button onclick='Volvo_BECMecuReset()'>Restart BECM module</button>";
|
||||
#endif // VOLVO_SPA_BATTERY
|
||||
|
||||
#if !defined(BMW_IX_BATTERY) && !defined(BOLT_AMPERA_BATTERY) && !defined(TESLA_BATTERY) && \
|
||||
!defined(NISSAN_LEAF_BATTERY) && !defined(BMW_I3_BATTERY) && !defined(BYD_ATTO_3_BATTERY) && \
|
||||
!defined(RENAULT_ZOE_GEN2_BATTERY) && !defined(CELLPOWER_BMS) && \
|
||||
!defined(MEB_BATTERY) // Only the listed types have extra info
|
||||
!defined(RENAULT_ZOE_GEN2_BATTERY) && !defined(CELLPOWER_BMS) && !defined(MEB_BATTERY) && \
|
||||
!defined(VOLVO_SPA_BATTERY) && !defined(KIA_HYUNDAI_64_BATTERY) //Only the listed types have extra info
|
||||
content += "No extra information available for this battery type";
|
||||
#endif
|
||||
|
||||
content += "</div>";
|
||||
|
||||
content += "<script>";
|
||||
content +=
|
||||
"function askClearIsolation() { if (window.confirm('Are you sure you want to clear any active isolation "
|
||||
"fault?')) { "
|
||||
"clearIsolation(); } }";
|
||||
content += "function clearIsolation() {";
|
||||
content += " var xhr = new XMLHttpRequest();";
|
||||
content += " xhr.open('GET', '/clearIsolation', true);";
|
||||
content += " xhr.send();";
|
||||
content += "}";
|
||||
content += "function goToMainPage() { window.location.href = '/'; }";
|
||||
content += "</script>";
|
||||
content += "<script>";
|
||||
content +=
|
||||
"function askResetSOH() { if (window.confirm('Are you sure you want to reset degradation data? "
|
||||
|
@ -1054,6 +1177,40 @@ String advanced_battery_processor(const String& var) {
|
|||
content += "}";
|
||||
content += "function goToMainPage() { window.location.href = '/'; }";
|
||||
content += "</script>";
|
||||
content += "<script>";
|
||||
content +=
|
||||
"function Volvo_askEraseDTC() { if (window.confirm('Are you sure you want to erase DTCs?')) { "
|
||||
"volvoEraseDTC(); } }";
|
||||
content += "function volvoEraseDTC() {";
|
||||
content += " var xhr = new XMLHttpRequest();";
|
||||
content += " xhr.open('GET', '/volvoEraseDTC', true);";
|
||||
content += " xhr.send();";
|
||||
content += "}";
|
||||
content += "function goToMainPage() { window.location.href = '/'; }";
|
||||
content += "</script>";
|
||||
|
||||
content += "<script>";
|
||||
content += "function Volvo_askReadDTC() { volvoReadDTC(); } ";
|
||||
content += "function volvoReadDTC() {";
|
||||
content += " var xhr = new XMLHttpRequest();";
|
||||
content += " xhr.open('GET', '/volvoReadDTC', true);";
|
||||
content += " xhr.send();";
|
||||
content += "}";
|
||||
content += "function goToMainPage() { window.location.href = '/'; }";
|
||||
content += "</script>";
|
||||
|
||||
content += "<script>";
|
||||
content +=
|
||||
"function Volvo_BECMecuReset() { if (window.confirm('Are you sure you want to restart BECM?')) { "
|
||||
"volvoBECMecuReset(); } }";
|
||||
content += "function volvoBECMecuReset() {";
|
||||
content += " var xhr = new XMLHttpRequest();";
|
||||
content += " xhr.open('GET', '/volvoBECMecuReset', true);";
|
||||
content += " xhr.send();";
|
||||
content += "}";
|
||||
content += "function goToMainPage() { window.location.href = '/'; }";
|
||||
content += "</script>";
|
||||
|
||||
return content;
|
||||
}
|
||||
return String();
|
||||
|
|