mirror of
https://github.com/dalathegreat/Battery-Emulator.git
synced 2025-10-03 09:49:32 +02:00
Add start for MysteryVan More Info page
This commit is contained in:
parent
30a7b9d90e
commit
fd2e5f2e52
3 changed files with 69 additions and 0 deletions
|
@ -191,6 +191,15 @@ void EcmpBattery::update_values() {
|
||||||
datalayer_extended.stellantisECMP.pid_contactor_closing_counter = pid_contactor_closing_counter;
|
datalayer_extended.stellantisECMP.pid_contactor_closing_counter = pid_contactor_closing_counter;
|
||||||
datalayer_extended.stellantisECMP.pid_date_of_manufacture = pid_date_of_manufacture;
|
datalayer_extended.stellantisECMP.pid_date_of_manufacture = pid_date_of_manufacture;
|
||||||
datalayer_extended.stellantisECMP.pid_SOH_cell_1 = pid_SOH_cell_1;
|
datalayer_extended.stellantisECMP.pid_SOH_cell_1 = pid_SOH_cell_1;
|
||||||
|
// Update extended datalayer for MysteryVan
|
||||||
|
datalayer_extended.stellantisECMP.MysteryVan = MysteryVan;
|
||||||
|
datalayer_extended.stellantisECMP.CrashMemorized = HV_BATT_CRASH_MEMORIZED;
|
||||||
|
datalayer_extended.stellantisECMP.CONTACTOR_OPENING_REASON = CONTACTOR_OPENING_REASON;
|
||||||
|
datalayer_extended.stellantisECMP.TBMU_FAULT_TYPE = TBMU_FAULT_TYPE;
|
||||||
|
datalayer_extended.stellantisECMP.HV_BATT_FC_INSU_MINUS_RES = HV_BATT_FC_INSU_MINUS_RES;
|
||||||
|
datalayer_extended.stellantisECMP.HV_BATT_FC_INSU_PLUS_RES = HV_BATT_FC_INSU_PLUS_RES;
|
||||||
|
datalayer_extended.stellantisECMP.HV_BATT_FC_VHL_INSU_PLUS_RES = HV_BATT_FC_VHL_INSU_PLUS_RES;
|
||||||
|
datalayer_extended.stellantisECMP.HV_BATT_ONLY_INSU_MINUS_RES = HV_BATT_ONLY_INSU_MINUS_RES;
|
||||||
|
|
||||||
if (battery_InterlockOpen) {
|
if (battery_InterlockOpen) {
|
||||||
set_event(EVENT_HVIL_FAILURE, 0);
|
set_event(EVENT_HVIL_FAILURE, 0);
|
||||||
|
|
|
@ -383,6 +383,58 @@ class EcmpHtmlRenderer : public BatteryHtmlRenderer {
|
||||||
: String(datalayer_extended.stellantisECMP.pid_SOH_cell_1)) +
|
: String(datalayer_extended.stellantisECMP.pid_SOH_cell_1)) +
|
||||||
"</h4>";
|
"</h4>";
|
||||||
|
|
||||||
|
if (datalayer_extended.stellantisECMP.MysteryVan) {
|
||||||
|
content += "<h4>MysteryVan platform detected: </h4>";
|
||||||
|
content += "<h4>Crash Memorized: ";
|
||||||
|
if (datalayer_extended.stellantisECMP.CrashMemorized == 255) {
|
||||||
|
content += "Yes</h4>";
|
||||||
|
} else {
|
||||||
|
content += "No</h4>";
|
||||||
|
}
|
||||||
|
content += "<h4>Contactor Opening Reason: ";
|
||||||
|
if (datalayer_extended.stellantisECMP.CONTACTOR_OPENING_REASON == 0) {
|
||||||
|
content += "No error";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.CONTACTOR_OPENING_REASON == 1) {
|
||||||
|
content += "Crash!";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.CONTACTOR_OPENING_REASON == 2) {
|
||||||
|
content += "12V supply source undervoltage";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.CONTACTOR_OPENING_REASON == 3) {
|
||||||
|
content += "12V supply source overvoltage";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.CONTACTOR_OPENING_REASON == 4) {
|
||||||
|
content += "Battery temperature";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.CONTACTOR_OPENING_REASON == 5) {
|
||||||
|
content += "Interlock line open";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.CONTACTOR_OPENING_REASON == 6) {
|
||||||
|
content += "e-Service plug disconnected";
|
||||||
|
}
|
||||||
|
content += "</h4>";
|
||||||
|
content += "<h4>Battery fault type: ";
|
||||||
|
if (datalayer_extended.stellantisECMP.TBMU_FAULT_TYPE == 0) {
|
||||||
|
content += "No fault";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.TBMU_FAULT_TYPE == 1) {
|
||||||
|
content += "FirstLevelFault: Warning Lamp";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.TBMU_FAULT_TYPE == 2) {
|
||||||
|
content += "SecondLevelFault: Stop Lamp";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.TBMU_FAULT_TYPE == 3) {
|
||||||
|
content += "ThirdLevelFault: Stop Lamp + contactor opening (EPS shutdown)";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.TBMU_FAULT_TYPE == 4) {
|
||||||
|
content += "FourthLevelFault: Stop Lamp + Active Discharge";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.TBMU_FAULT_TYPE == 5) {
|
||||||
|
content += "Inhibition of powertrain activation";
|
||||||
|
} else if (datalayer_extended.stellantisECMP.TBMU_FAULT_TYPE == 6) {
|
||||||
|
content += "Reserved";
|
||||||
|
}
|
||||||
|
content += "</h4>";
|
||||||
|
content += "<h4>FC insulation minus resistance " +
|
||||||
|
String(datalayer_extended.stellantisECMP.HV_BATT_FC_INSU_MINUS_RES) + " kOhm</h4>";
|
||||||
|
content += "<h4>FC insulation plus resistance " +
|
||||||
|
String(datalayer_extended.stellantisECMP.HV_BATT_FC_INSU_PLUS_RES) + " kOhm</h4>";
|
||||||
|
content += "<h4>FC vehicle insulation plus resistance " +
|
||||||
|
String(datalayer_extended.stellantisECMP.HV_BATT_FC_VHL_INSU_PLUS_RES) + " kOhm</h4>";
|
||||||
|
content += "<h4>FC vehicle insulation plus resistance " +
|
||||||
|
String(datalayer_extended.stellantisECMP.HV_BATT_ONLY_INSU_MINUS_RES) + " kOhm</h4>";
|
||||||
|
}
|
||||||
|
|
||||||
return content;
|
return content;
|
||||||
}
|
}
|
||||||
};
|
};
|
||||||
|
|
|
@ -235,6 +235,14 @@ struct DATALAYER_INFO_CMFAEV {
|
||||||
};
|
};
|
||||||
|
|
||||||
struct DATALAYER_INFO_ECMP {
|
struct DATALAYER_INFO_ECMP {
|
||||||
|
//mysteryvan parameters
|
||||||
|
bool MysteryVan = false;
|
||||||
|
bool CrashMemorized = false;
|
||||||
|
uint8_t CONTACTOR_OPENING_REASON = 0;
|
||||||
|
uint8_t TBMU_FAULT_TYPE = 0;
|
||||||
|
uint16_t HV_BATT_FC_INSU_MINUS_RES, HV_BATT_FC_INSU_PLUS_RES, HV_BATT_FC_VHL_INSU_PLUS_RES,
|
||||||
|
HV_BATT_ONLY_INSU_MINUS_RES = 0;
|
||||||
|
//ecmp below
|
||||||
uint8_t MainConnectorState = 0;
|
uint8_t MainConnectorState = 0;
|
||||||
uint16_t InsulationResistance = 0;
|
uint16_t InsulationResistance = 0;
|
||||||
uint8_t InsulationDiag = 0;
|
uint8_t InsulationDiag = 0;
|
||||||
|
|
Loading…
Add table
Add a link