#include "USER_SETTINGS.h" /* This file contains all the battery settings and limits */ /* They can be defined here, or later on in the WebUI */ /* Battery settings */ volatile uint16_t BATTERY_WH_MAX = 30000; //Battery size in Wh (Maximum value for most inverters is 65000 [65kWh], you can use larger batteries but do not set value over 65000! volatile uint16_t MAXPERCENTAGE = 800; //80.0% , Max percentage the battery will charge to (App will show 100% once this value is reached) volatile uint16_t MINPERCENTAGE = 200; //20.0% , Min percentage the battery will discharge to (App will show 0% once this value is reached) volatile uint16_t MAXCHARGEAMP = 300; //30.0A , BYD CAN specific setting, Max charge speed in Amp (Some inverters needs to be artificially limited) volatile uint16_t MAXDISCHARGEAMP = 300; //30.0A , BYD CAN specific setting, Max discharge speed in Amp (Some inverters needs to be artificially limited) #ifdef WEBSERVER #define ENABLE_AP // Comment out this line to turn off the broadcasted AP const char* ssid = "REPLACE_WITH_YOUR_SSID"; // Maximum of 63 characters; const char* password = "REPLACE_WITH_YOUR_PASSWORD"; // Minimum of 8 characters; const char* ssidAP = "Battery Emulator"; // Maximum of 63 characters; const char* passwordAP = "123456789"; // Minimum of 8 characters; set to NULL if you want the access point to be open const char* versionNumber = "4.3.0"; // The current software version, shown on webserver #endif