#ifndef __USER_SETTINGS_H__
|
|
#define __USER_SETTINGS_H__
|
|
|
|
/* This file contains all the user configurable settings for the Battery-Emulator software */
|
|
/* To switch between batteries/inverters, uncomment a line to enable, comment out to disable. */
|
|
/* There are also some options for battery limits and extra functionality */
|
|
|
|
/* Select battery used */
|
|
#define BATTERY_TYPE_LEAF
|
|
//#define TESLA_MODEL_3_BATTERY
|
|
//#define RENAULT_ZOE_BATTERY
|
|
//#define BMW_I3_BATTERY
|
|
//#define IMIEV_ION_CZERO_BATTERY
|
|
//#define KIA_HYUNDAI_64_BATTERY
|
|
//#define CHADEMO
|
|
|
|
/* Select inverter communication protocol. See Wiki for which to use with your inverter: https://github.com/dalathegreat/BYD-Battery-Emulator-For-Gen24/wiki */
|
|
#define MODBUS_BYD //Enable this line to emulate a "BYD 11kWh HVM battery" over Modbus RTU
|
|
//#define MODBUS_LUNA2000 //Enable this line to emulate a "Luna2000 battery" over Modbus RTU
|
|
//#define CAN_BYD //Enable this line to emulate a "BYD Battery-Box Premium HVS" over CAN Bus
|
|
//#define SOLAX_CAN //Enable this line to emulate a "SolaX Triple Power LFP" over CAN bus
|
|
//#define PYLON_CAN //Enable this line to emulate a "Pylontech battery" over CAN bus
|
|
//#define SMA_CAN //Enable this line to emulate a "BYD Battery-Box H 8.9kWh, 7 mod" over CAN bus
|
|
//#define SOFAR_CAN //Enable this line to emulate a "Sofar Energy Storage Inverter High Voltage BMS General Protocol (Extended Frame)" over CAN bus
|
|
|
|
/* Battery settings */
|
|
#define BATTERY_WH_MAX 30000 //Battery size in Wh (Maximum value for most inverters is 60000 [60kWh], you can use larger batteries but do set value over 60000!
|
|
#define MAXPERCENTAGE 800 //80.0% , Max percentage the battery will charge to (App will show 100% once this value is reached)
|
|
#define MINPERCENTAGE 200 //20.0% , Min percentage the battery will discharge to (App will show 0% once this value is reached)
|
|
//define INTERLOCK_REQUIRED //Nissan LEAF specific setting, if enabled requires both high voltage conenctors to be seated before starting
|
|
|
|
/* Other options */
|
|
#define DEBUG_VIA_USB //Enable this line to have the USB port output serial diagnostic data while program runs
|
|
//#define CONTACTOR_CONTROL //Enable this line to have pins 25,32,33 handle automatic precharge/contactor+/contactor- closing sequence
|
|
//#define PWM_CONTACTOR_CONTROL //Enable this line to use PWM logic for contactors, which lower power consumption and heat generation
|
|
//#define DUAL_CAN //Enable this line to activate an isolated secondary CAN Bus using add-on MCP2515 controller (Needed for FoxESS inverters)
|
|
|
|
#endif |