/* Select battery used */
|
|
#define BATTERY_TYPE_LEAF // See NISSAN-LEAF-BATTERY.h for more LEAF battery settings
|
|
//#define TESLA_MODEL_3_BATTERY // See TESLA-MODEL-3-BATTERY.h for more Tesla battery settings
|
|
//#define RENAULT_ZOE_BATTERY // See RENAULT-ZOE-BATTERY.h for more Zoe battery settings
|
|
//#define CHADEMO // See CHADEMO.h for more Chademo related settings
|
|
|
|
/* Select inverter communication protocol. See Wiki for which to use with your inverter: https://github.com/dalathegreat/BYD-Battery-Emulator-For-Gen24/wiki */
|
|
#define MODBUS_BYD //Enable this line to emulate a "BYD 11kWh HVM battery" over Modbus RTU
|
|
//#define CAN_BYD //Enable this line to emulate a "BYD Battery-Box Premium HVS" over CAN Bus
|
|
//#define SOLAX_CAN //Enable this line to emulate a "SolaX Triple Power LFP" over CAN bus
|
|
//#define PYLON_CAN //Enable this line to emulate a "Pylontech battery" over CAN bus
|
|
|
|
/* Do not change any code below this line unless you are sure what you are doing */
|
|
/* Only change battery specific settings and limits in their respective .h files */
|
|
|
|
#include <Arduino.h>
|
|
#include "HardwareSerial.h"
|
|
#include "config.h"
|
|
#include "Logging.h"
|
|
#include "mbServerFCs.h"
|
|
#include "ModbusServerRTU.h"
|
|
#include "ESP32CAN.h"
|
|
#include "CAN_config.h"
|
|
#include "Adafruit_NeoPixel.h"
|
|
#include "BATTERIES.h"
|
|
#include "INVERTERS.h"
|
|
//CAN parameters
|
|
#define MAX_CAN_FAILURES 5000 //Amount of malformed CAN messages to allow before raising a warning
|
|
CAN_device_t CAN_cfg; // CAN Config
|
|
const int rx_queue_size = 10; // Receive Queue size
|
|
|
|
//Interval settings
|
|
const int intervalInverterTask = 4800; //Interval at which to refresh modbus registers / inverter values
|
|
const int interval10 = 10; //Interval for 10ms tasks
|
|
unsigned long previousMillis10ms = 50;
|
|
|
|
//ModbusRTU parameters
|
|
unsigned long previousMillisModbus = 0; //will store last time a modbus register refresh
|
|
#define MB_RTU_NUM_VALUES 30000
|
|
uint16_t mbPV[MB_RTU_NUM_VALUES]; // process variable memory: produced by sensors, etc., cyclic read by PLC via modbus TCP
|
|
|
|
//Gen24 parameters
|
|
#define STANDBY 0
|
|
#define INACTIVE 1
|
|
#define DARKSTART 2
|
|
#define ACTIVE 3
|
|
#define FAULT 4
|
|
#define UPDATING 5
|
|
uint16_t capacity_Wh_startup = BATTERY_WH_MAX;
|
|
uint16_t max_power = 40960; //41kW
|
|
const uint16_t max_voltage = ABSOLUTE_MAX_VOLTAGE; //if higher charging is not possible (goes into forced discharge)
|
|
const uint16_t min_voltage = ABSOLUTE_MIN_VOLTAGE; //if lower Gen24 disables battery
|
|
uint16_t min_volt_byd_can = min_voltage;
|
|
uint16_t max_volt_byd_can = max_voltage;
|
|
uint16_t min_volt_solax_can = min_voltage;
|
|
uint16_t max_volt_solax_can = max_voltage;
|
|
uint16_t min_volt_pylon_can = min_voltage;
|
|
uint16_t max_volt_pylon_can = max_voltage;
|
|
|
|
uint16_t battery_voltage = 3700;
|
|
uint16_t battery_current = 0;
|
|
uint16_t SOC = 5000; //SOC 0-100.00% //Updates later on from CAN
|
|
uint16_t StateOfHealth = 9900; //SOH 0-100.00% //Updates later on from CAN
|
|
uint16_t capacity_Wh = BATTERY_WH_MAX; //Updates later on from CAN
|
|
uint16_t remaining_capacity_Wh = BATTERY_WH_MAX; //Updates later on from CAN
|
|
uint16_t max_target_discharge_power = 0; //0W (0W > restricts to no discharge) //Updates later on from CAN
|
|
uint16_t max_target_charge_power = 4312; //4.3kW (during charge), both 307&308 can be set (>0) at the same time //Updates later on from CAN. Max value is 30000W
|
|
uint16_t temperature_max = 50; //reads from battery later
|
|
uint16_t temperature_min = 60; //reads from battery later
|
|
uint16_t bms_char_dis_status; //0 idle, 1 discharging, 2, charging
|
|
uint16_t bms_status = ACTIVE; //ACTIVE - [0..5]<>[STANDBY,INACTIVE,DARKSTART,ACTIVE,FAULT,UPDATING]
|
|
uint16_t stat_batt_power = 0; //power going in/out of battery
|
|
|
|
// Create a ModbusRTU server instance listening on Serial2 with 2000ms timeout
|
|
ModbusServerRTU MBserver(Serial2, 2000);
|
|
|
|
// LED control
|
|
Adafruit_NeoPixel pixels(1, WS2812_PIN, NEO_GRB + NEO_KHZ800);
|
|
static int green = 0;
|
|
static bool rampUp = true;
|
|
const int maxBrightness = 255;
|
|
|
|
//Contactor parameters
|
|
enum State {
|
|
WAITING_FOR_BATTERY,
|
|
PRECHARGE,
|
|
NEGATIVE,
|
|
POSITIVE,
|
|
PRECHARGE_OFF,
|
|
COMPLETED,
|
|
SHUTDOWN_REQUESTED
|
|
};
|
|
State contactorStatus = WAITING_FOR_BATTERY;
|
|
#define PRECHARGE_TIME_MS 160
|
|
#define NEGATIVE_CONTACTOR_TIME_MS 1000
|
|
#define POSITIVE_CONTACTOR_TIME_MS 2000
|
|
unsigned long prechargeStartTime = 0;
|
|
unsigned long negativeStartTime = 0;
|
|
unsigned long timeSpentInFaultedMode = 0;
|
|
uint8_t batteryAllowsContactorClosing = 0;
|
|
|
|
// Setup() - initialization happens here
|
|
void setup()
|
|
{
|
|
//CAN pins
|
|
pinMode(CAN_SE_PIN, OUTPUT);
|
|
digitalWrite(CAN_SE_PIN, LOW);
|
|
CAN_cfg.speed = CAN_SPEED_500KBPS;
|
|
CAN_cfg.tx_pin_id = GPIO_NUM_27;
|
|
CAN_cfg.rx_pin_id = GPIO_NUM_26;
|
|
CAN_cfg.rx_queue = xQueueCreate(rx_queue_size, sizeof(CAN_frame_t));
|
|
// Init CAN Module
|
|
ESP32Can.CANInit();
|
|
Serial.println(CAN_cfg.speed);
|
|
|
|
//Init contactor pins
|
|
pinMode(POSITIVE_CONTACTOR_PIN, OUTPUT);
|
|
digitalWrite(POSITIVE_CONTACTOR_PIN, LOW);
|
|
pinMode(NEGATIVE_CONTACTOR_PIN, OUTPUT);
|
|
digitalWrite(NEGATIVE_CONTACTOR_PIN, LOW);
|
|
pinMode(PRECHARGE_PIN, OUTPUT);
|
|
digitalWrite(PRECHARGE_PIN, LOW);
|
|
|
|
// Init Serial monitor
|
|
Serial.begin(9600);
|
|
while (!Serial)
|
|
{
|
|
}
|
|
Serial.println("__ OK __");
|
|
|
|
//Set up Modbus RTU Server
|
|
pinMode(RS485_EN_PIN, OUTPUT);
|
|
digitalWrite(RS485_EN_PIN, HIGH);
|
|
|
|
pinMode(RS485_SE_PIN, OUTPUT);
|
|
digitalWrite(RS485_SE_PIN, HIGH);
|
|
|
|
pinMode(PIN_5V_EN, OUTPUT);
|
|
digitalWrite(PIN_5V_EN, HIGH);
|
|
|
|
// Init Static data to the RTU Modbus
|
|
handle_static_data_modbus();
|
|
|
|
// Init Serial2 connected to the RTU Modbus
|
|
RTUutils::prepareHardwareSerial(Serial2);
|
|
Serial2.begin(9600, SERIAL_8N1, RS485_RX_PIN, RS485_TX_PIN);
|
|
|
|
// Register served function code worker for server
|
|
MBserver.registerWorker(MBTCP_ID, READ_HOLD_REGISTER, &FC03);
|
|
MBserver.registerWorker(MBTCP_ID, WRITE_HOLD_REGISTER, &FC06);
|
|
MBserver.registerWorker(MBTCP_ID, WRITE_MULT_REGISTERS, &FC16);
|
|
MBserver.registerWorker(MBTCP_ID, R_W_MULT_REGISTERS, &FC23);
|
|
|
|
// Start ModbusRTU background task
|
|
MBserver.begin(Serial2);
|
|
|
|
// Init LED control
|
|
pixels.begin();
|
|
pixels.setPixelColor(0, pixels.Color(0, 0, 255)); // Blue LED full brightness while battery and CAN is starting.
|
|
pixels.show(); // Incase of crash due to CAN polarity / termination, LED will remain BLUE
|
|
|
|
//Inform user what setup is used
|
|
#ifdef BATTERY_TYPE_LEAF
|
|
Serial.println("Nissan LEAF battery selected");
|
|
#endif
|
|
#ifdef TESLA_MODEL_3_BATTERY
|
|
Serial.println("Tesla Model 3 battery selected");
|
|
#endif
|
|
#ifdef RENAULT_ZOE_BATTERY
|
|
Serial.println("Renault Zoe battery selected");
|
|
#endif
|
|
}
|
|
|
|
// perform main program functions
|
|
void loop()
|
|
{
|
|
handle_can(); //runs as fast as possible, handle CAN routines
|
|
|
|
if (millis() - previousMillis10ms >= interval10) //every 10ms
|
|
{
|
|
previousMillis10ms = millis();
|
|
handle_LED_state(); //Set the LED color according to state
|
|
handle_contactors(); //Take care of startup precharge/contactor closing
|
|
}
|
|
|
|
if (millis() - previousMillisModbus >= intervalInverterTask) //every 5s
|
|
{
|
|
previousMillisModbus = millis();
|
|
handle_inverter(); //Update values heading towards inverter
|
|
}
|
|
}
|
|
|
|
void handle_can()
|
|
{ //This section checks if we have a complete CAN message incoming
|
|
//Depending on which battery/inverter is selected, we forward this to their respective CAN routines
|
|
CAN_frame_t rx_frame;
|
|
if (xQueueReceive(CAN_cfg.rx_queue, &rx_frame, 3 * portTICK_PERIOD_MS) == pdTRUE)
|
|
{
|
|
if (rx_frame.FIR.B.FF == CAN_frame_std)
|
|
{
|
|
//printf("New standard frame");
|
|
#ifdef BATTERY_TYPE_LEAF
|
|
receive_can_leaf_battery(rx_frame);
|
|
#endif
|
|
#ifdef TESLA_MODEL_3_BATTERY
|
|
receive_can_tesla_model_3_battery(rx_frame);
|
|
#endif
|
|
#ifdef RENAULT_ZOE_BATTERY
|
|
receive_can_zoe_battery(rx_frame);
|
|
#endif
|
|
#ifdef CAN_BYD
|
|
receive_can_byd(rx_frame);
|
|
#endif
|
|
#ifdef CHADEMO
|
|
receive_can_chademo(rx_frame);
|
|
#endif
|
|
}
|
|
else
|
|
{
|
|
//printf("New extended frame");
|
|
#ifdef SOLAX_CAN
|
|
receive_can_solax(rx_frame);
|
|
#endif
|
|
#ifdef PYLON_CAN
|
|
receive_can_pylon(rx_frame);
|
|
#endif
|
|
}
|
|
}
|
|
//When we are done checking if a CAN message has arrived, we can focus on sending CAN messages
|
|
//Inverter sending
|
|
#ifdef CAN_BYD
|
|
send_can_byd();
|
|
#endif
|
|
#ifdef SOLAX_CAN
|
|
send_can_solax();
|
|
#endif
|
|
//Battery sending
|
|
#ifdef BATTERY_TYPE_LEAF
|
|
send_can_leaf_battery();
|
|
#endif
|
|
#ifdef TESLA_MODEL_3_BATTERY
|
|
send_can_tesla_model_3_battery();
|
|
#endif
|
|
#ifdef RENAULT_ZOE_BATTERY
|
|
send_can_zoe_battery();
|
|
#endif
|
|
#ifdef CHADEMO
|
|
send_can_chademo_battery();
|
|
#endif
|
|
}
|
|
|
|
void handle_inverter()
|
|
{
|
|
#ifdef BATTERY_TYPE_LEAF
|
|
update_values_leaf_battery(); //Map the values to the correct registers
|
|
#endif
|
|
#ifdef TESLA_MODEL_3_BATTERY
|
|
update_values_tesla_model_3_battery(); //Map the values to the correct registers
|
|
#endif
|
|
#ifdef RENAULT_ZOE_BATTERY
|
|
update_values_zoe_battery(); //Map the values to the correct registers
|
|
#endif
|
|
#ifdef SOLAX_CAN
|
|
update_values_can_solax();
|
|
#endif
|
|
#ifdef CAN_BYD
|
|
update_values_can_byd();
|
|
#endif
|
|
#ifdef PYLON_CAN
|
|
update_values_can_pylon();
|
|
#endif
|
|
#ifdef CHADEMO
|
|
update_values_can_chademo();
|
|
#endif
|
|
|
|
//Updata for ModbusRTU Server for GEN24
|
|
handle_update_data_modbusp201();
|
|
handle_update_data_modbusp301();
|
|
}
|
|
|
|
void handle_contactors()
|
|
{
|
|
//First check if we have any active errors, incase we do, turn off the battery after 15 seconds
|
|
if(bms_status == FAULT)
|
|
{
|
|
timeSpentInFaultedMode++;
|
|
}
|
|
if(timeSpentInFaultedMode > 1500)
|
|
{
|
|
contactorStatus = SHUTDOWN_REQUESTED;
|
|
}
|
|
if(contactorStatus == SHUTDOWN_REQUESTED)
|
|
{
|
|
digitalWrite(PRECHARGE_PIN, LOW);
|
|
digitalWrite(NEGATIVE_CONTACTOR_PIN, LOW);
|
|
digitalWrite(POSITIVE_CONTACTOR_PIN, LOW);
|
|
return;
|
|
}
|
|
|
|
//After that, check if we are OK to start turning on the battery
|
|
if(contactorStatus == WAITING_FOR_BATTERY)
|
|
{
|
|
if(batteryAllowsContactorClosing)
|
|
{
|
|
contactorStatus = PRECHARGE;
|
|
}
|
|
}
|
|
|
|
if(contactorStatus == COMPLETED)
|
|
{ //Skip running the state machine below if it has already completed
|
|
return;
|
|
}
|
|
|
|
unsigned long currentTime = millis();
|
|
//Handle actual state machine. This first turns on Precharge, then Negative, then Positive, and finally turns OFF precharge
|
|
switch (contactorStatus) {
|
|
case PRECHARGE:
|
|
digitalWrite(PRECHARGE_PIN, HIGH);
|
|
prechargeStartTime = currentTime;
|
|
contactorStatus = NEGATIVE;
|
|
break;
|
|
|
|
case NEGATIVE:
|
|
if (currentTime - prechargeStartTime >= PRECHARGE_TIME_MS) {
|
|
digitalWrite(NEGATIVE_CONTACTOR_PIN, HIGH);
|
|
negativeStartTime = currentTime;
|
|
contactorStatus = POSITIVE;
|
|
}
|
|
break;
|
|
|
|
case POSITIVE:
|
|
if (currentTime - negativeStartTime >= NEGATIVE_CONTACTOR_TIME_MS) {
|
|
digitalWrite(POSITIVE_CONTACTOR_PIN, HIGH);
|
|
contactorStatus = PRECHARGE_OFF;
|
|
}
|
|
break;
|
|
|
|
case PRECHARGE_OFF:
|
|
if (currentTime - negativeStartTime >= POSITIVE_CONTACTOR_TIME_MS) {
|
|
digitalWrite(PRECHARGE_PIN, LOW);
|
|
contactorStatus = COMPLETED;
|
|
}
|
|
break;
|
|
default:
|
|
break;
|
|
}
|
|
}
|
|
|
|
void handle_static_data_modbus() {
|
|
// Store the data into the array
|
|
static uint16_t si_data[] = { 21321, 1 };
|
|
static uint16_t byd_data[] = { 16985, 17408, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 };
|
|
static uint16_t battery_data[] = { 16985, 17440, 16993, 29812, 25970, 31021, 17007, 30752, 20594, 25965, 26997, 27936, 18518, 0, 0, 0 };
|
|
static uint16_t volt_data[] = { 13614, 12288, 0, 0, 0, 0, 0, 0, 13102, 12598, 0, 0, 0, 0, 0, 0 };
|
|
static uint16_t serial_data[] = { 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 };
|
|
static uint16_t static_data[] = { 1, 0 };
|
|
static uint16_t* data_array_pointers[] = { si_data, byd_data, battery_data, volt_data, serial_data, static_data };
|
|
static uint16_t data_sizes[] = { sizeof(si_data), sizeof(byd_data), sizeof(battery_data), sizeof(volt_data), sizeof(serial_data), sizeof(static_data) };
|
|
static uint16_t i = 100;
|
|
for (uint8_t arr_idx = 0; arr_idx < sizeof(data_array_pointers) / sizeof(uint16_t*); arr_idx++) {
|
|
uint16_t data_size = data_sizes[arr_idx];
|
|
memcpy(&mbPV[i], data_array_pointers[arr_idx], data_size);
|
|
i += data_size / sizeof(uint16_t);
|
|
}
|
|
}
|
|
|
|
void handle_update_data_modbusp201() {
|
|
// Store the data into the array
|
|
static uint16_t system_data[13];
|
|
system_data[0] = 0; // Id.: p201 Value.: 0 Scaled value.: 0 Comment.: Always 0
|
|
system_data[1] = 0; // Id.: p202 Value.: 0 Scaled value.: 0 Comment.: Always 0
|
|
system_data[2] = (capacity_Wh_startup); // Id.: p203 Value.: 32000 Scaled value.: 32kWh Comment.: Capacity rated, maximum value is 60000 (60kWh)
|
|
system_data[3] = (max_power); // Id.: p204 Value.: 32000 Scaled value.: 32kWh Comment.: Nominal capacity
|
|
system_data[4] = (max_power); // Id.: p205 Value.: 14500 Scaled value.: 30,42kW Comment.: Max Charge/Discharge Power=10.24kW (lowest value of 204 and 205 will be enforced by Gen24)
|
|
system_data[5] = (max_voltage); // Id.: p206 Value.: 3667 Scaled value.: 362,7VDC Comment.: Max Voltage, if higher charging is not possible (goes into forced discharge)
|
|
system_data[6] = (min_voltage); // Id.: p207 Value.: 2776 Scaled value.: 277,6VDC Comment.: Min Voltage, if lower Gen24 disables battery
|
|
system_data[7] = 53248; // Id.: p208 Value.: 53248 Scaled value.: 53248 Comment.: Always 53248 for this BYD, Peak Charge power?
|
|
system_data[8] = 10; // Id.: p209 Value.: 10 Scaled value.: 10 Comment.: Always 10
|
|
system_data[9] = 53248; // Id.: p210 Value.: 53248 Scaled value.: 53248 Comment.: Always 53248 for this BYD, Peak Discharge power?
|
|
system_data[10] = 10; // Id.: p211 Value.: 10 Scaled value.: 10 Comment.: Always 10
|
|
system_data[11] = 0; // Id.: p212 Value.: 0 Scaled value.: 0 Comment.: Always 0
|
|
system_data[12] = 0; // Id.: p213 Value.: 0 Scaled value.: 0 Comment.: Always 0
|
|
static uint16_t i = 200;
|
|
memcpy(&mbPV[i], system_data, sizeof(system_data));
|
|
}
|
|
|
|
void handle_update_data_modbusp301() {
|
|
// Store the data into the array
|
|
static uint16_t battery_data[24];
|
|
if (battery_current > 0) { //Positive value = Charging
|
|
bms_char_dis_status = 2; //Charging
|
|
} else if (battery_current < 0) { //Negative value = Discharging
|
|
bms_char_dis_status = 1; //Discharging
|
|
} else { //battery_current == 0
|
|
bms_char_dis_status = 0; //idle
|
|
}
|
|
|
|
if (bms_status == ACTIVE) {
|
|
battery_data[8] = battery_voltage; // Id.: p309 Value.: 3161 Scaled value.: 316,1VDC Comment.: Batt Voltage outer (0 if status !=3, maybe a contactor closes when active): 173.4V
|
|
} else {
|
|
battery_data[8] = 0;
|
|
}
|
|
battery_data[0] = bms_status; // Id.: p301 Value.: 3 Scaled value.: 3 Comment.: status(*): ACTIVE - [0..5]<>[STANDBY,INACTIVE,DARKSTART,ACTIVE,FAULT,UPDATING]
|
|
battery_data[1] = 0; // Id.: p302 Value.: 0 Scaled value.: 0 Comment.: always 0
|
|
battery_data[2] = 128 + bms_char_dis_status; // Id.: p303 Value.: 130 Scaled value.: 130 Comment.: mode(*): normal
|
|
battery_data[3] = SOC; // Id.: p304 Value.: 1700 Scaled value.: 50% Comment.: SOC: (50% would equal 5000)
|
|
battery_data[4] = capacity_Wh; // Id.: p305 Value.: 32000 Scaled value.: 32kWh Comment.: tot cap:
|
|
battery_data[5] = remaining_capacity_Wh; // Id.: p306 Value.: 13260 Scaled value.: 13,26kWh Comment.: remaining cap: 7.68kWh
|
|
battery_data[6] = max_target_discharge_power; // Id.: p307 Value.: 25604 Scaled value.: 25,604kW Comment.: max/target discharge power: 0W (0W > restricts to no discharge)
|
|
battery_data[7] = max_target_charge_power; // Id.: p308 Value.: 25604 Scaled value.: 25,604kW Comment.: max/target charge power: 4.3kW (during charge), both 307&308 can be set (>0) at the same time
|
|
//Battery_data[8] set previously in function // Id.: p309 Value.: 3161 Scaled value.: 316,1VDC Comment.: Batt Voltage outer (0 if status !=3, maybe a contactor closes when active): 173.4V
|
|
battery_data[9] = 2000; // Id.: p310 Value.: 64121 Scaled value.: 6412,1W Comment.: Current Power to API: if>32768... -(65535-61760)=3775W
|
|
battery_data[10] = battery_voltage; // Id.: p311 Value.: 3161 Scaled value.: 316,1VDC Comment.: Batt Voltage inner: 173.2V (LEAF voltage is in whole volts, need to add a decimal)
|
|
battery_data[11] = 2000; // Id.: p312 Value.: 64121 Scaled value.: 6412,1W Comment.: p310
|
|
battery_data[12] = temperature_min; // Id.: p313 Value.: 75 Scaled value.: 7,5 Comment.: temp min: 7 degrees (if below 0....65535-t)
|
|
battery_data[13] = temperature_max; // Id.: p314 Value.: 95 Scaled value.: 9,5 Comment.: temp max: 9 degrees (if below 0....65535-t)
|
|
battery_data[14] = 0; // Id.: p315 Value.: 0 Scaled value.: 0 Comment.: always 0
|
|
battery_data[15] = 0; // Id.: p316 Value.: 0 Scaled value.: 0 Comment.: always 0
|
|
battery_data[16] = 16; // Id.: p317 Value.: 0 Scaled value.: 0 Comment.: counter charge hi
|
|
battery_data[17] = 22741; // Id.: p318 Value.: 0 Scaled value.: 0 Comment.: counter charge lo....65536*101+9912 = 6629048 Wh?
|
|
battery_data[18] = 0; // Id.: p319 Value.: 0 Scaled value.: 0 Comment.: always 0
|
|
battery_data[19] = 0; // Id.: p320 Value.: 0 Scaled value.: 0 Comment.: always 0
|
|
battery_data[20] = 13; // Id.: p321 Value.: 0 Scaled value.: 0 Comment.: counter discharge hi
|
|
battery_data[21] = 52064; // Id.: p322 Value.: 0 Scaled value.: 0 Comment.: counter discharge lo....65536*92+7448 = 6036760 Wh?
|
|
battery_data[22] = 230; // Id.: p323 Value.: 0 Scaled value.: 0 Comment.: device temperature (23 degrees)
|
|
battery_data[23] = StateOfHealth; // Id.: p324 Value.: 9900 Scaled value.: 99% Comment.: SOH
|
|
static uint16_t i = 300;
|
|
memcpy(&mbPV[i], battery_data, sizeof(battery_data));
|
|
}
|
|
|
|
void handle_LED_state()
|
|
{
|
|
// Determine how bright the green LED should be
|
|
if (rampUp && green < maxBrightness)
|
|
{
|
|
green++;
|
|
}
|
|
else if (rampUp && green == maxBrightness)
|
|
{
|
|
rampUp = false;
|
|
}
|
|
else if (!rampUp && green > 0)
|
|
{
|
|
green--;
|
|
} else if (!rampUp && green == 0)
|
|
{
|
|
rampUp = true;
|
|
}
|
|
pixels.setPixelColor(0, pixels.Color(0, green, 0)); // Set LED to green according to calculated value
|
|
|
|
if(CANerror > MAX_CAN_FAILURES)
|
|
{
|
|
pixels.setPixelColor(0, pixels.Color(255, 255, 0)); // Yellow LED full brightness
|
|
}
|
|
|
|
if(bms_status == FAULT)
|
|
{
|
|
pixels.setPixelColor(0, pixels.Color(255, 0, 0)); // Red LED full brightness
|
|
}
|
|
|
|
pixels.show(); // This sends the updated pixel color to the hardware.
|
|
}
|