Battery-Emulator/Software/src/battery/VOLVO-SPA-HTML.h

155 lines
5.2 KiB
C++

#ifndef _VOLVO_SPA_HTML_H
#define _VOLVO_SPA_HTML_H
#include "../datalayer/datalayer.h"
#include "../datalayer/datalayer_extended.h"
#include "../devboard/webserver/BatteryHtmlRenderer.h"
class VolvoSpaHtmlRenderer : public BatteryHtmlRenderer {
public:
String get_status_html() {
String content;
content += "</h4><h4>BECM reported number of DTCs: " + String(datalayer_extended.VolvoPolestar.DTCcount) + "</h4>";
content += "<h4>BECM reported SOC: " + String(datalayer_extended.VolvoPolestar.soc_bms / 10.0) + " %</h4>";
content += "<h4>Calculated SOC: " + String(datalayer_extended.VolvoPolestar.soc_calc / 10.0) + " %</h4>";
content += "<h4>Rescaled SOC: " + String(datalayer_extended.VolvoPolestar.soc_rescaled / 100.0) + " %</h4>";
content += "<h4>BECM reported SOH: " + String(datalayer_extended.VolvoPolestar.soh_bms / 100.0) + " %</h4>";
content += "<h4>BECM supply voltage: " + String(datalayer_extended.VolvoPolestar.BECMsupplyVoltage) + " mV</h4>";
content += "<h4>HV voltage: " + String(datalayer_extended.VolvoPolestar.BECMBatteryVoltage) + " V</h4>";
content += "<h4>HV current: " + String(datalayer_extended.VolvoPolestar.BECMBatteryCurrent) + " A</h4>";
content += "<h4>Dynamic max voltage: " + String(datalayer_extended.VolvoPolestar.BECMUDynMaxLim) + " V</h4>";
content += "<h4>Dynamic min voltage: " + String(datalayer_extended.VolvoPolestar.BECMUDynMinLim) + " V</h4>";
content +=
"<h4>Discharge power limit 1: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimDcha1) + " kW</h4>";
content +=
"<h4>Discharge soft power limit: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimDchaSoft) + " kW</h4>";
content +=
"<h4>Discharge power limit slow aging: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimDchaSlowAgi) +
" kW</h4>";
content +=
"<h4>Charge power limit slow aging: " + String(datalayer_extended.VolvoPolestar.HvBattPwrLimChrgSlowAgi) +
" kW</h4>";
content += "<h4>HVIL Circuit A status: ";
switch (datalayer_extended.VolvoPolestar.HVILstatusBits & 0x01) {
case 0x01:
content += String("Open");
break;
default:
content += String("Not valid");
}
content += "<h4>HVIL Circuit B status: ";
switch (datalayer_extended.VolvoPolestar.HVILstatusBits & 0x02) {
case 0x02:
content += String("Open");
break;
default:
content += String("Closed");
}
content += "<h4>HVIL Circuit C status: ";
switch (datalayer_extended.VolvoPolestar.HVILstatusBits & 0x04) {
case 0x04:
content += String("Open");
break;
default:
content += String("Closed");
}
content += "<h4>Precharge contactor status: ";
switch (datalayer_extended.VolvoPolestar.HVILstatusBits & 0x08) {
case 0x08:
content += String("Open");
break;
default:
content += String("Closed");
}
content += "<h4>Positive Contactor status: ";
switch (datalayer_extended.VolvoPolestar.HVILstatusBits & 0x10) {
case 0x10:
content += String("Open");
break;
default:
content += String("Closed");
}
content += "<h4>Negative Contactor status: ";
switch (datalayer_extended.VolvoPolestar.HVILstatusBits & 0x20) {
case 0x20:
content += String("Open");
break;
default:
content += String("Closed");
}
content += "<h4>HV system relay status: ";
switch (datalayer_extended.VolvoPolestar.HVSysRlySts) {
case 0:
content += String("Open");
break;
case 1:
content += String("Closed");
break;
case 2:
content += String("KeepStatus");
break;
case 3:
content += String("OpenAndRequestActiveDischarge");
break;
default:
content += String("Not valid");
}
content += "</h4><h4>HV system relay status 1: ";
switch (datalayer_extended.VolvoPolestar.HVSysDCRlySts1) {
case 0:
content += String("Open");
break;
case 1:
content += String("Closed");
break;
case 2:
content += String("KeepStatus");
break;
case 3:
content += String("Fault");
break;
default:
content += String("Not valid");
}
content += "</h4><h4>HV system relay status 2: ";
switch (datalayer_extended.VolvoPolestar.HVSysDCRlySts2) {
case 0:
content += String("Open");
break;
case 1:
content += String("Closed");
break;
case 2:
content += String("KeepStatus");
break;
case 3:
content += String("Fault");
break;
default:
content += String("Not valid");
}
content += "</h4><h4>HV system isolation resistance monitoring status: ";
switch (datalayer_extended.VolvoPolestar.HVSysIsoRMonrSts) {
case 0:
content += String("Not valid 1");
break;
case 1:
content += String("False");
break;
case 2:
content += String("True");
break;
case 3:
content += String("Not valid 2");
break;
default:
content += String("Not valid");
}
return content;
}
};
#endif